sop for retesting for raw materials
1.0 Purpose
1.1 To describe a procedure for Re-Testing for Raw Materials (active and excipients)
2.0 Scope
2.1 This procedure is applicable for Re-Testing for Raw Materials located at Quality control department at ABC Pvt. Ltd.
3.0 Responsibility
Officer QC/ Executive QC Preparation of SOP and follow the procedure as per SOP
Assistant Manager Reviewing and Training of SOP
Manager QC Implementation of SOP
4.0 Accountability
4.1 Manager Quality Control is accountable for implementation and compliance with SOP.
5.0 Procedure
5.1 All the raw materials shall be re-tested after 1 year from the date of approval.
5.2 In case of product having short expiry with comparison to retest date then retest date will
be remain as NA (Not Applicable).
5.3 Date of re-test shall be mentioned on the “Approved label” pasted on the approved raw materials.
Without re-testing and re-approval from Quality control department, the raw material shall
not be issued by store department.
5.4 Active raw materials and excipients shall be re-tested till the expiry or 03 years whichever is earlier before.
5.5 The list of the raw materials, due for re-testing, in a month are printed from the Store department.
5.6 The Officer / Executive QA shall ensure that the respective raw material shall be sampled, tested
and released due for re-testing.
5.7 The raw materials (to be re-tested) shall be sampled as per sampling SOP No. QCD-013.
5.8 The raw material shall be tested for parameters like description, assay as per their current STP,
and related substances and any other specific test.
5.9 If material conforms to the specification approval shall be given and “Approved” label shall be
pasted on material. Blocked materials shall then be un-blocked by the Store personnel.
5.10 A suffix ‘R” is added to the existing AR No. to identify it as a re-test material. However, for dispensing
purpose the original AR No. shall remain intact.
5.11 In case material does not conform to the specification, the material shall be rejected, and the
Store department shall be informed.
5.12 Paste the “Rejected” label on rejected material, and ensure that material is shifted from approve area to rejected area.
6.0 Reference
In house specification
7.0 Attachments
Not Applicable
8.0 Distribution
Distribution of the controlled copy to concerned departments.
Additional copies may be issued for specific purpose.
9.0 Abbreviations
QA : Quality Assurance
QC : Quality Control
SOP : Standard Operating Procedure
A.R. : Analytical Report
STP : Standard Testing Procedure
10.0 Revision History
| Revision No. | Supersedes | Effective Date | Details of reason |
| 01 | Nil | New SOP |
Operating Procedure of Centrifuge
sop for preparation and storage of reagent solution
sop for Calibration and Maintenance of Laboratory Instruments and Equipment
Disposal of Residual Sample or Left Over Material
sop for for Laboratory Incident
standard operating procedure temperature monitoring
sop for operation of infrared moisture balance
sop for preparation of mobile phase
sop for Preparation and Issuance of Analysis protocol standard
sop of placebo and impurity stock solutions
sop for disposal of residual sample
sop for handling of pharmacopoeial changes
sop for procedure for operation of ultrasonic cleaner
difference between UPLC and HPLC
sop for for Emergency Eyewash and Shower
sop for operation and calibration of total organic carbon analyzers
sop for operation of cobb tester
sop for Operation and calibration of atomic absorption spectrophotometer
sop for Operation and calibration of gas liquid chromatograph
sop for operation of humidity oven
sop for operation and calibration of serological water bath
sop for monitoring of drain trap
sop for destruction of analytical samples after testing and control samples
sop for destruction of used chemicals
Sop for Operation of suction pump
sop for Operation and calibration uv cabinet
sop for Operation and calibration of bulk density apparatus
sop for operation and calibration of shore hardness tester
sop for operation of rub proofness tester
sop for monitoring of purified water
sop for Retesting of packaging materials
sop for Retesting and resampling of raw materials
sop for Control of issuance of record of analysis green sheets
sop for Control of computer passwords
sop for sampling of packaging materials PM
Operation and Calibration Procedure for pH Meter
operation and calibration of muffle furnace
Operation and cleaning of centrifuge
Operation and cleaning of sonicator
Operation and calibration of dissolution test apparatus
Operation and cleaning of hot air oven
Operation and calibration of bursting strength
Operating procedure of refrigerator
Operating procedure of stop watch
sop for retesting for raw materials