master formula record diazepam injection injection

 

master formula record diazepam injection injection

NAME    OF   PRODUCT                     : diazepam injection 

COMPOSITION                                    : Each ml Contains:

Diazepam  5 mg

Benzyl Alcohol   1.5 % w/v

Water for injection I.P. q.s.

BATCH SIZE                                        : 100 Litres

SELF  LIFE                                            : 2 Years

PACKAGING                                        : 10 ml White Vials



MANUFACTURING  FORMULA    :

Sr. No. Raw Material Qty Per ml Overages Total qty per ml Quantity per batch
01. Diazepam 5mg 5mg 500gm
02. Benzoic Acid 0.044mg 0.044mg   44gm
03. Sodium Benzoate 0.8mg 0.8mg  800gm
04. Benzyl Alcohol 1.5% 1.5%  1.50lit.
05. Propylene Glycol 70% 70%  70.0lit.
06. Water for injection Q.S. Q.S.  Q.S.

CALCULATION    :    Diazepam 5.0mg

 

For each ml

 

100

_____________  x 5 mg x  100 Litres

(Assay – Water)

 

( Assay according to Quality Control Report )

EQUIPMENT   USED  :

PROCESS STEGE                                  EQUIPMENT AND VESSELS

1)  DISPENSING                                     (a) Weighing Machine

(b) S.S.Scoop

(c)  S.S.Containers/Polybags

 

2) BULK MANUFACTURING               (a) 50 Litre  S.S.Tank with lid  and stirre.

(b) 100 Litre S.S.Tank with lid  and stirre.

(c) 142 mm/293 mm filter assembly.

3) FILTERATION                                     (a) Bubble point Apparatus

(b)  Filtration Assembly – 142 mm /293 mm

(c)  20 litres/50 litres receivingVessels / filling tank

(d) Autoclave .

4) FILLING & SEALING                         (a) Vial filling and sealing machine

(b) S.S.Container / Tray

5) VIAL WASHING                                  (a) Vial washing machine

(b) S.S.Boxes / Tray

(c) Dry Heat Sterilization (D.H.S.)

6) OPTICAL TESTING                              (a) Optical testing tables.

7) BATCH  PRINTING                              (a) Batch printing machine

8) LABELLING & PACKING                   (a) Labelling machine

(b)Taping machine

(c) Strepping machine

GENERAL   DISPENSING   PROCEDURES   :

THE MAIN STEPS IN DISPENSING AREA    :

Transaction    with   Raw   Material    Store         :

Depending upon the production programme and availability of raw materials,bulk requisitions duly authorized by  Production  Manager  /  Mfg . Chemist , must be given to store , 2 hour’s in  advance . While  receiving the materials should be checked by concerned Supervisor for the following :-

  1. a) Label
  2. b) A.R. Number from Q.C.
  3. c) Quantity
  4. d) Checking of weight in the weighing room
  5. e) Physical damage if any.

DISPENSING

On receiving the raw materials requisition, the materials are dispensed in the following manner.



DEPACKING

Materials contained in polythene bags are first depacked  into  s.s.container  and  duly  labeled  . Materials     received in fibre drums and carbous  need not be depacked, only external cleaning with a clean dry cloth is sufficient.

WEIGHING

The materials are  dispensed as per the  requisition duly authorized by  Production Manager  /  Mfg.Chemist  received from the production department. The materials are weighed on electronic balance. All the materials dispensed are weighed by on Supervisor and counter checked by another Supervisor.

BULK MANUFACTURING :

1) Clean all the equipment /containers required for bulk manufacturing with (teepol/liquid soap) rinse it with tape water and D.M.Water.
2) In the bulk manufacturing area rinsed twice all the above mentioned items with fresh distilled water.
3) Collect 70 litres Propylene glycol in the tank and start nitrogen flushing 30 minutes.
4) Then add Benzyl alcohol , Diazepam and then add Benzoic Acid with continuous sterring.
5) Collect 2 litres water for injection then add Sodium Benzoate.
6) Fanally add solution no.3,4and 5with continous sterring.
7) Finaly check and adjust the pH between 6.2 to 6.9 .
8) Make up the volume upto 100 litres.

PREPARATION OF FILTER ASSEMBLY :

 

To  be  done  under  controlled  environment  ,  use 142 mm  / 293 mm filter assembly . Before using , dismantle all parts of the assembly like plates, lower plate, upper plate, clamps, nozzles , distributors, gasket  ,  distributing net etc  .  wash them with teepol , raw water and then washed with hot distilled water  .cool them for better handling.

 

Mounting is done as follows:

  • Put lower plate on legs.
  • Put distributing net on lower plate on that the sieve is kept.
  • Put membrane filter on sieve, do not touch the paper on any surface. Put some distilled water on the paper so it get soaked. Put the pre filter on it,
  • Put the upper plate with gasket properly fitted.
  • Clamp the filter assembly. Tighten the opposite clamps at a time to avoid any leakages.
  • Fix latex tubing.
  • Perform bubble point test at 40 pound pressure. If it passes the bubble point then sterilize it. If it fails then mount  the  filter  paper  again  .  Filter assembly should not be fully airtight while sterilizing.

 

Sterilization of filter assembly is done at 117 C for 30 minutes. After sterilization, filter the prepared batch  ,  filtered the solution in  sterilized S. S. receiving vessels. Bubble point test perform before and after the filtration.

 

VIAL WASHING :

  • Decarton the vials in clean plastic creates in aseptic area.
  • Transfer the creates in washing room.
  • Arrange these vials in S.S. trays.
  • Load tray in vials washing machine.
  • Put on the cycle.
  • vials are washed through unit with 5 micron filtered D.M. water with alternate the flushing with filtered compressed air.
  • Unload the machine and arrange.
  • The vials into S.S. tray for dry heat sterilizations.

 

STERILIZATION :

To be sterilized at minimum 200° C for 1 hour.

STERILIZATION OF SOLUTION :

 

The  product is  aseptically  filled .  Sterilization is  achieved  by  filtering  through a  membrane filter. Filteration is done through a 142 mm/293 mm membrane filter of 0.22 micron size. Prefilter1.5micron used is 142 mm/293 mm.

 

FILLING :

  1. FILLING UNIT :

It consist, of S.S. syringes, holders, filling needles, gassing needles, silicone tubing etc.

 

The above should be first cleaned carefully with teepol, raw water and then washed with hot distilled water. After cleaning. Syringes deeped in distilled water and kept in S.S. tank which are then invaded into the autoclave for sterilizing. The sterilization cycle is 117 ° C for 30 minutes.

 

  1. RECEIVING VESSELS :

Vessels which  are used to  collect  the  filtered  solution  have to be first  washed with teepol solution steamed, then washed with hot distilled water and taken into the unit preparation area. Here they are rinsed twice with fresh distilled water  .  The opening of  vessals are then   sterilized at  117 0 C  for  30 minutes.

  1. GARMENTS :

Garments that are used in the sterile filling area are first checked if they are torn  .  Torn  garments are rejected. Clean garments are then folded property and two sets are put into one sterilization box open loaded into the autoclave for  sterilization .  The  sterilization  cycle  is  117 ° C  for  30 minutes .  After   sterilization the perforation are closed .  The  garments are  taken to the  air lock and are hanged on to hangers.

  1. GLOVES  :

New gloves are washed thoroughly with DM water and then with distilled water. The gloves are also checked for any tearing and if found any, rejected . These gloves are then put into s.s. unit boxes with the perforation open and sterilized at 117 0 C for 30 minutes.

 

FILING OPERATION :




Filling of vials with sterile solution is done in sterile area. Vials filling is done on one head vial filling and sealing machine.

Filling capacity of the machine is 30 vials per minute . During filling, the production supervisor has to conduct creation in process control test at regular interval.
In process Test Frequency
a. Fill volume 10.0 to10.50 ml 30 minutes
b. Nitrogen gassing is proper or not every one hour
c. Optical checking every one hour
d. Sealing quality every one hour
write filing is going on movement should be restrained and there should be less talking. The machine should be kept clean.
During lunch break the full area should be cleaned , spraying of antiseptic solution should be taken up at regular intervals.

STERILIZATION :
Sterilization by filteration.

VISUAL INSPECTION :
Vials are taken for visual inspection . Visual inspection is done on inspection table.The inspection is fitted with a source of illumination such as tube light .The screen has half the area paintedwith white and half the area painted in black.The front of the light is covered so that the direct light does not fall on the a separate table . The vials are checked by swirling its contects by wrist movement and observe for any particleor foreign matters .There should be a gap of 5 to 10minutes after one hour of working. Trained operators should only be allowed.

Type of rejection :
1) Black particles
2) White particles
3) Fibres
4) Glass particles
5) Shining matters
6) Sealing rejection
7) Less / high volume
8) Breakage

Product  Name                     : Diazepam injection 10 ml Vial

 

Self  life                                : 2 Years

 

Colour                                   :  Clear, colourless solution.

 

Contents                                :  10.5 ml

 

pH                                        :  6.2 to 6.9

 

Assay                                    :  Diazepam 5.0mg

 

Limit 90.0 % to 110.0%

 

Theoretical  yield  at  different  stages :

Scheduled fill                                        : 9523       yield           permissible limit

 

Filling rejection 1.5 %                           : 143        9380            0 to 2.5%

 

Optical  checking rejection  6%             :  571        8809           0 to 8.0 %

 

Total rejection                                        :  714

 

Normal yield                                          :  8809

 

After optical inspection vials are kept on labeling machine .

 

PACKING  DETAILS  :  Box of 24  x  10 ml

Outer of 10 x 24 x 10 ml

 

INPROCESS CONTROLS :

 

PRINTING :

At the start of the batch the printing of the labels should be checked and signed by competent person.

 

LABELLING  :

Periodic check has to be done so that the labeled ampoules have a good aesthetic appearance.

CODING :

Vial labels are overprinted in label printing machine / by hand stamping with batch no. ,Mfg. date, Exp.Date , Retail price and any specific instruction.

PROCEDURE :

Vials are labeled on labeling machine after getting line clearance . The capacity of the machine is 120 vials per minutes.The ampoules are checked for authentic appearance and any cross labeled / dirty labeled vials are delabelled and labeled again .After labeling vials are kept in cartons, inner boxes and then kept in outer boxes . Outer boxes are passed for taping with printed BOPP tape by taping machine. After packing
is over left out labels are counted and destroyed .

FINISHED PRODUCT :

After final packing store in a segregated storage area .Finished products which are “ UNDER TEST ’’ must be quarantined and segregated by fixed printed labels.

master formula record cyproheptadine hcl and tricholine citrate syrup

master formula record l-carnitine injection

master formula record etofylline and theophylline injection

master formula record ranitidine injection

master formula record tranexamic acid injection

master formula record tranexamic acid injection

master formula record cetirizine syrup

MFR of sucralfate oral suspension

Master formula record Quinine Sulphate Suspension

MFR of Paracetamol Phenylephrine Hcl Chlorpheniramine Maleate Drops

master formula record paracetamol oral suspension

master formula record ethamsylate 250 mg injection 2 ml

master formula record ofloxacin oral suspension

master formula record Fluconazole Cream

master formula record ondansetron oral solution

MFR of hydroxyzine hydrochloride oral solution

master formula record vitamin D3 drops

master formula record furazolidone oral suspension

MFR of Clobetasol Propionate cream 

master formula record Povidone iodine ointment 5%

MFR of Magaldrate Simethicone and Oxetacaine Suspension

master formula record albendazole oral suspension

master formula record ondansetron injection

master formula record nandrolone decanoate injection

MFR of iron sucrose injection

MFR of diclofenac sodium injection

master formula record dicylomine hydrochloride injection

Leave a Comment

error: Content is protected !!