Procedure For Analysis of Water rinsing

 

Procedure For Analysis of Water rinsing

 

1.0 Objective
To define a procedure for analysis of rinsing water samples received from production dept. so as

to as certain the equipments free from previous contamination.
2.0 Scope
Rinsing water samples received from production department at abc Pvt. Ltd.
3.0 Responsibility
3.1 Executive – Quality Control.
3.2 In charge/Head-Quality Control.
4.0 Abbreviations and Definitions
SOP : Standard Operating Procedure
QC : Quality Control
CC NO : Change Control Number
cGMP : Current Good Manufacturing Practice
G : General
5.0 Procedure
5.1 The frequency of analysis of water rinses will be as and when sample is received from production dept.
5.2 Production department will send the intimation along with water rinsing and blank

sample i.e. purified water used for washing.
5.3 The rinsing water will be analyzed by spectrophotometer method.
5.4 The rinsing water will be analyzed by spectrophotometer method.
5.5 Test preparation: water rinsings.
5.6 Blank: Purified water used for washing.
5.7 Determine the absorbance of standard and test preparation using Distilled water as

blank on a UV/Visible Spectrophotometer in the region 200nm-600nm.
5.8 Interpretation: The absorbance of test preparation should not be more than that of

standard preparation when scanned in the above region. If the absorbance of the test

preparation is more than that of the standard, then the washing of the particular equipment

and machinery should be continued till the rinsings show less absorbance than the standard.
5.9 Rinse sample will also analyzed for conductivity and for ph and these both the should

comply as per the limit for purified water.
5.10 Analysis the sample for colour used in previous product manufactured.
5.11 Note: The standard graphs are scanned and maintained for comparison purpose.
5.12 The results of analysis should be filled in the blank report format signed by the analyst and

the group in charge and should be send to production department.
6.0 Forms and Records
6.1 None.
7.0 Distribution
7.1 Master copy – Documentation Cell (Quality Assurance)
7.2 Control copy – Quality Assurance, Quality Control
8.0 History

Revision Number Details For Change
Reason for Revision
00 New SOP NA

Operating Procedure of Centrifuge

sop for preparation and storage of reagent solution

sop for Calibration and Maintenance of Laboratory Instruments and Equipment

Disposal of Residual Sample or Left Over Material

sop for for Laboratory Incident

standard operating procedure temperature monitoring

sop for drying of silica gel

sop for operation of infrared moisture balance

sop for preparation of mobile phase

sop for treated RO water

sop for Preparation and Issuance of Analysis protocol standard

sop of placebo and impurity stock solutions

sop for disposal of residual sample  

sop for handling of pharmacopoeial changes

sop for procedure for operation of ultrasonic cleaner

difference between UPLC and HPLC

sop for for Emergency Eyewash and Shower

sop for operation and calibration of total organic carbon analyzers

sop for operation of cobb tester

sop for Operation and calibration of atomic absorption spectrophotometer

sop for Operation and calibration of gas liquid chromatograph

sop for operation of humidity oven

sop for operation and calibration of serological water bath

sop for monitoring of drain trap

sop for destruction of analytical samples after testing and control samples

sop for destruction of used chemicals

Sop for Operation of suction pump

sop for Operation and calibration uv cabinet

sop for Operation and calibration of bulk density apparatus

sop for operation and calibration of shore hardness tester

sop for operation of rub proofness tester

sop for monitoring of purified water

sop for Retesting of packaging materials

sop for Retesting and resampling of raw materials

sop for Control of issuance of record of analysis green sheets

sop for Control of computer passwords

sop for sampling of packaging materials PM

Operation and Calibration Procedure for pH Meter

Calibration of Melting Point Apparatus

Procedure For HPLC column washing procedure

Procedure For Retest Period of Raw Material

Procedure For Training Programme For Quality Control Personnel

Standard Operating Procedure is to provide guidelines for Preparation

Procedure For Analysis of Water rinsing

Leave a Comment

error: Content is protected !!