General Test Procedure Weight per ML and Specific Gravity

General Test Procedure Weight per ML and Specific Gravity   Purpose This procedure is applicable to all incoming Raw materials, In-process and Finished products. Apparatus Pycnometer specific gravity bottle Calibrated glass thermometer Balance Reagents None. Procedure Procedure for Volumetric Flask Take the wt. of empty Pycnometer. Fill the Pycnometer with liquid and maintain at 25°C … Read more

General Test Procedure Melting Range and Freezing Point

  General Test Procedure Melting Range and Freezing Point   Purpose This procedure is applicable to all incoming Raw materials, In-process and Finished products. Apparatus Melting point apparatus Thin-walled capillary glass tubes of hard glass, closed at one end pestle mortar Beakers Test tubes Water bath Calibrated glass thermometer Balance Reagents None Procedure Procedure for … Read more

General Test Procedure Sulphated ash

General Test Procedure Sulphated ash   purpose This procedure is applicable to all incoming Raw materials. Apparatus Muffle furnace Balance Silica or Platinum or porcelain or quartz crucibles Graduated pipette1 ml Hot plate Desiccator Nickel tongue Reagents Sulphuric acid Procedure Keep crucible in muffle furnace at temperature 800° ± 25°C for 30 minutes. Take out … Read more

General Test Procedure Water Content

      General Test Procedure Water Content Purpose This procedure is applicable to all incoming Raw materials, In-process and Finished products. Apparatus Karl Fischer Apparatus Reagents Karl Fisher Reagent Methanol (Dried) Disodium Tartrate Procedure Unless otherwise specified, weigh/measure accurately a suitable quantity of sample containing about                 … Read more

General Test Procedure pH

                  General Test Procedure pH Purpose This procedure is applicable to all incoming Raw materials, In-process and Finished products. Apparatus pH Meter calibrated thermometer Calibrated Balance Reagents Potassium chloride Procedure Operate the pH meter as per the Standard Operating Procedure. Check whether pH meter is calibrated or … Read more

General Test Procedure Loss on drying

General Test Procedure Loss on drying Purpose This procedure is applicable to all incoming Raw materials, In-process and Finished products. Apparatus Hot air oven/vacuum oven calibrated thermometer Calibrated Balance Reagents None Procedure Weigh a glass stoppered, shallow weighing bottle that has been dried under the same conditions to be             … Read more

General Test Procedure Specific Optical Rotation

General Test Procedure Specific Optical Rotation   Purpose This procedure is applicable to all incoming materials. Apparatus Polarimeter Polarimeter Tube Calibrated Balance Thermometer Reagents None Procedure The optical rotation, a, unless otherwise specified, is measured at the wavelength of the sodium D-line (589.3 nm) at a temperature of 25° in a layer 1 dm thick. … Read more

General Test Procedure Identification by Solubility

  General Test Procedure Identification by Solubility Purpose This procedure is applicable to all incoming Raw materials, In-process and Finished products. Apparatus Calibrated Balance. Reagents Solvent as mentioned in STP Procedure Weigh accurately a suitable quantity of sample into a glass stoppered test tube and add specified                 … Read more

General Test Procedure Identification by UV

  General Test Procedure Identification by UV   Purpose This procedure is applicable to all incoming Raw materials, In-process and Finished products. Apparatus UV-Visible spectrophotometer Quartz Cuvettes or Quartz Cells (1.0 cm) Reagents Freshly distilled Water Solvents as specified : AR Grade Chemicals as specified : AR Grade Procedure Set the spectrophotometer in the photometric … Read more

General Test Procedure Identification by TLC

General Test Procedure Identification by TLC Purpose This procedure is applicable to incoming Raw materials, in process and finished products. Apparatus Thin Layer Chromatographic Plates Micro syringes Micropipettes Calibrated disposable capillaries TLC chamber UV chamber Reagents None Procedure Prepare mobile phase by mixing solvents in the ratio as per given in the individual test. Procedure … Read more

error: Content is protected !!