1.0 Purpose
1.1 To describe a procedure for operation and cleaning of water bath.

2.0 Scope
2.1 This standard operating procedure is applicable for operation and cleaning of water bath at

Chemical Analysis Room in Quality Control department at ABC  Pvt. Ltd.

3.0 Responsibility
Officer QC/ Executive QC Preparation of SOP
Assistant Manager Reviewing and Training of SOP
Manager QC Implementation of SOP
4.0 Accountability
Manager Quality Control is accountable for implementation and compliance with SOP.

5.0 Procedure
5.1 Operation
5.1.1 Clean the instrument with clean and dry cloth. If required use the wet cloth followed dry cloth.
5.1.2 Ensure that power supply should be OFF from main supply.
5.1.3 Fill the sufficient purified water into the water bath so that heater is merged and at

least water level is 2 cm above the heater.
5.1.4 Switch ON the Water Bath from the main supply of power.
5.1.5 Close the all holes with lids of water bath.
5.1.6 Wait till boil the water and than in use.

5.2 Cleaning
5.2.1 For cleaning the bath change the water weekly basis or as required
5.2.2 Drain the previously filled water
5.2.3 Clean the bath with 2% liquid soap & rinse with potable water & purified water respectively.

5.3 Precaution
5.3.1 Handle the instrument properly.
5.3.2 Do not start the heater if there is no water in the Water Bath.
5.3.3 The water bath should be filled with purified water only.
5.3.4 Quality control Manager or his designee informs the defect to maintenance department to

rectify the problem. Affix Under Maintenance label on the instrument.

6.0 Reference
In House

7.0 Attachments
Not Applicable

8.0 Distribution
Distribution of the controlled copy to concerned departments.
Additional copies may be issued for specific purpose.
9.0 Abbreviations
QA : Quality Assurance
QC : Quality Control
SOP : Standard Operating Procedure

10.0 Revision History

Revision No. Supersedes Effective Date. Details of Revision
01 Nil New SOP

 

Operating Procedure of Centrifuge

sop for preparation and storage of reagent solution

sop for Calibration and Maintenance of Laboratory Instruments and Equipment

Disposal of Residual Sample or Left Over Material

sop for for Laboratory Incident

standard operating procedure temperature monitoring

sop for drying of silica gel

sop for operation of infrared moisture balance

sop for preparation of mobile phase

sop for treated RO water

sop for Preparation and Issuance of Analysis protocol standard

sop of placebo and impurity stock solutions

sop for disposal of residual sample  

sop for handling of pharmacopoeial changes

sop for procedure for operation of ultrasonic cleaner

difference between UPLC and HPLC

sop for for Emergency Eyewash and Shower

sop for operation and calibration of total organic carbon analyzers

sop for operation of cobb tester

sop for Operation and calibration of atomic absorption spectrophotometer

sop for Operation and calibration of gas liquid chromatograph

sop for operation of humidity oven

sop for operation and calibration of serological water bath

sop for monitoring of drain trap

sop for destruction of analytical samples after testing and control samples

sop for destruction of used chemicals

Sop for Operation of suction pump

sop for Operation and calibration uv cabinet

sop for Operation and calibration of bulk density apparatus

sop for operation and calibration of shore hardness tester

sop for operation of rub proofness tester

sop for monitoring of purified water

sop for Retesting of packaging materials

sop for Retesting and resampling of raw materials

sop for Control of issuance of record of analysis green sheets

sop for Control of computer passwords

sop for sampling of packaging materials PM

Operation and Calibration Procedure for pH Meter

Calibration of Melting Point Apparatus

Procedure For HPLC column washing procedure

Procedure For Retest Period of Raw Material

Procedure For Training Programme For Quality Control Personnel

Standard Operating Procedure is to provide guidelines for Preparation

Procedure For Analysis of Water rinsing

Procedure For Calibration of Glassware

Procedure For Procurement and storage of reference standards

Procedure For Preparation of buffer solution

safety guidelines for laboratory

responsibilities of quality control and microbiological department

responsibilities of quality control and microbiological department

handling of corrosive hazardous and flammable chemical

cleaning of glassware

calibration of volumetric glassware

operation and cleaning of water bath

Exit mobile version