General Test Procedure Identification by Solubility

  General Test Procedure Identification by Solubility Purpose This procedure is applicable to all incoming Raw materials, In-process and Finished products. Apparatus Calibrated Balance. Reagents Solvent as mentioned in STP Procedure Weigh accurately a suitable quantity of sample into a glass stoppered test tube and add specified                 … Read more

General Test Procedure Identification by UV

  General Test Procedure Identification by UV   Purpose This procedure is applicable to all incoming Raw materials, In-process and Finished products. Apparatus UV-Visible spectrophotometer Quartz Cuvettes or Quartz Cells (1.0 cm) Reagents Freshly distilled Water Solvents as specified : AR Grade Chemicals as specified : AR Grade Procedure Set the spectrophotometer in the photometric … Read more

General Test Procedure Identification by TLC

General Test Procedure Identification by TLC Purpose This procedure is applicable to incoming Raw materials, in process and finished products. Apparatus Thin Layer Chromatographic Plates Micro syringes Micropipettes Calibrated disposable capillaries TLC chamber UV chamber Reagents None Procedure Prepare mobile phase by mixing solvents in the ratio as per given in the individual test. Procedure … Read more

General Test Procedure Identification by HPLC

  General Test Procedure Identification by HPLC Purpose This procedure is applicable to all incoming Raw materials, In-process and Finished products. Apparatus HPLC Column HPLC Vial Reagents HPLC grade Water HPLC grade chemicals Procedure Compare the retention time of standard and sample in the assay test as mentioned in the assay method. The major peak … Read more

General Test Procedure Identification by IR

        General Test Procedure Identification by IR   1.0  Purpose 1.1  This procedure is applicable to all incoming raw materials. 2.0  Apparatus 2.1  Infrared Spectrophotometer 2.2  Hydraulic Pellet Press 2.3  Lab Oven 2.4  Analytical Balance 3.0 Reagents 3.1 Potassium Bromide spectroscopic grade 3.2 Liquid Paraffin AR grade 3.3 Sodium chloride 4.0 Procedure … Read more

Analysis of Glimepiride and Metformin Hydrochloride (SR) Tablets

  Analysis of Glimepiride and Metformin Hydrochloride (SR) Tablets   Description  :  Take 10 tablets, observed visually & record. Identification As per Assay procedure: Positive test for Glimepiride & Metformin Hydrochloride. Average Weight :  Weigh accurately 20 tablets, note down the weight and divide the gross weight by 20 to obtain         … Read more

cleaning of dry syrup powder filling machine

  CLEANING OF DRY SYRUP POWDER FILLING MACHINE 1. Put off the electric connections. 2. Dismantle the nozzle, hopper, auger and the main shaft and transfer them to the equipment cleaning room. 3. Wash all the parts with hot water and a soap solution (10% soap and 1% disinfectant) ning soft nylon wire brush. 4. … Read more

sop for cleaning of double cone blender

  CLEANING OF DOUBLE CONE BLENDER 1.Caution :Disconnect the equipment from electrical main supply. 2. Set the position of the blender vertical-butterfly valve facing the floor A )  PROCEDURE FOR PRODUCT TO PRODUCT CHANGEOVER 1. Dismantling- a. Remove the safety guard of the blender b. Remove the circular lid and gasket by unclamping wing nuts. … Read more