analysis of Acarbose 25 mg Tablet
analysis of Acarbose 25 mg Tablet 01. Description : Remove 20 tablets from the strip. Place on a white paper and observe visually. 02. Average Weight: Weigh accurately 20 tablets and calculate … Read more
analysis of Acarbose 25 mg Tablet 01. Description : Remove 20 tablets from the strip. Place on a white paper and observe visually. 02. Average Weight: Weigh accurately 20 tablets and calculate … Read more
analysis of Albendazole Suspension standard testing procedure albendazole Suspension 1.0 OBJECTIVE 1.1 To lay down a procedure for analysis of Albendazole Suspension. 2.0 SCOPE 2.1 This procedure is applicable to the analysis of Albendazole Suspension. in QC lab at abc pharma. 3.0 RESPONSIBILITY 3.1 Q.C- Chemist 4.0 ACCOUNTABILITY 4.1 Manager-Quality Assurance 5.1 Description: … Read more
List of Instruments Quality Control Department Quality control instrument is used in chemical, instrumental and microbiological testing pharmaceuticals and other sector Example Apathic, Ayurveda Unani drugs as per given standards. The list of instruments used in Quality Control department. 1) HPLC ( High Performance Liquid Chromatography) 2) FTIR ( Fourier transform infrared) 3) … Read more
standard test procedure ampicillin and cloxacillin capsules Description VISUAL EXAMINATION IDENTIFICATION :- As per assay Average weight & Weight variation (Content): Equipment : A suitable analytical balance. Procedure : Select 20 capsules from composite sample & weight accurately (a) . Now weight an intact capsule. Open the capsules without losing any part of shell … Read more
Standard test procedure of raw Material Iron sucrose 1.0 OBJECTIVE 1.1 To lay down a procedure for Analysis of Iron sucrose. 2.0 SCOPE 2.1 This procedure is applicable to the Analysis of Iron sucrose in QC lab 3.0 RESPONSIBILITY 3.1 Q.C- Chemist 4.0 ACCOUNTABILITY 4.1 Head-Quality Assurance 5.0 Definition: – Iron contains NLT 4.8 … Read more
standard test procedure aceclofenac and paracetamol tablets Description : By visually inspection Identification: The retention time of the major peaks for Aceclofenac & paracetamol obtained from assay preparation should correspond to that of standard preparation as described under the assay . Average Weight & Uniformity of Weight : Equipment : A … Read more
Analysis of diclofenac gel 1.0 OBJECTIVE 1.1 To lay down a procedure for analysis of Diclofenac GEL. 2.0 SCOPE 2.1 This procedure is applicable to the analysis of Diclofenac GEL.in quality control laboratory 3.0 RESPONSIBILITY 3.1 Q.C- Chemist 4.0 ACCOUNTABILITY 4.1 Head-Quality Assurance 5.0 PROCEDURE: 5.1 Description: Pour 50ml finish sample in beaker and observed … Read more
Analysis of Nystatin ointment 100000 Units per gram 1.0 OBJECTIVE 1.1 To lay down a procedure for Analysis of Nystatin Ointment. 2.0 SCOPE 2.1 This procedure is applicable to the analysis of Nystatin Ointment.in Quality control laboratories 3.0 RESPONSIBILITY 3.1 Q.C- Chemist 4.0 ACCOUNTABILITY 4.1 Manager-Quality Assurance 5.0 PROCEDURE 5.1 Description: Pour … Read more
stp of Analysis of Hydrochloric acid 1.0 OBJECTIVE 1.1 To lay down a procedure for Analysis of Hydrochloric acid. 2.0 SCOPE 2.1 This procedure is applicable to the Analysis of Hydrochloric acid.in QC lab 3.0 RESPONSIBILITY 3.1 Q.C- Chemist 4.0 ACCOUNTABILITY 4.1 Head-Quality Assurance 5.0 DEFINITION: – Hydrochloric acid contains NLT 35.0 % … Read more
BACTERIAL ENDOTOXIN TEST FOR DEXAMETHASONE INJECTION 1.0 EQUIPMENT REQUIRED LAF, Heating Block, Cyclo Mixer, Micropipettes, 2.0 MATERIAL REQUIRED CSE, LYSATE, LRW, Depyrogenated dilution tube 13mm X 100mm, Depyrogenated assay tube 12mm X 75mm, Individually packed Sterile, Endotoxin free micropipette tips. 3.0 General: 3.1 Clean all the required glassware and dehydrogenated all the glassware. … Read more