1.0 OBJECTIVE: 

To lay down a procedure for sampling of packing materials so as to get the representative sample of the whole lot.

2.0 RESPONSIBILITY

2.1 The Officer / Assistant – Quality Control Packaging

2.2 The Executive – Quality Assurance
3.0 ACCOUNTABILITY

Executive – Quality Assurance



4.0 PROCEDURE:
4.1 Receive Goods Receipt Note (GRN) from Warehouse and record relevant information’s in packaging material register.
4.2 Take out Photocopy of Sampler’s Check List – PM
4.3 The separate sampler’s remark shall be used for each lot of Batches.
4.4 Prepare the “UNDER TEST” label from the computer system to affix on the consignment.
4.5 Check the delivered items to ensure that the quantity received corresponds with the GRN Quantity
4.6 Fill the necessary details in Sampler’s Check List by taking the reference of Goods Receipt Note (GRN). If discrepancy found in GRN inform to warehouse for corrective action.
4.7 Go to the Quarantine area and identify the material to be sampled from Quarantined label which is affixed by Warehouse on the packs.
4.8 In case of Aluminium and PVC foils carry out the sampling under Laminar Air Flow (LAF).
4.9 Cleaning of LAF shall be carried out on every alternate day or early if required. The LAF shall be cleaned with wet mop followed by dry mop.
4.10 The cleaning shall be recorded in the cleaning record for LAF
4.11 Ensure that the surrounding area is clean, if not get it cleans, prior to start of the sampling.
4.12 Check the packing condition of the material and details mentioned on the Under Test labels.
4.13 Verify that the Quarantine Labels are affixed by Warehouse Personnel.
4.14 In case of any discrepancies intimate to Executive / Head – Quality Assurance or Head – Quality Control for necessary action.
4.15 Ensure that packs are cleaned externally and open the packages only after ensuring the proper cleaning. Observe the material for any abnormalities and record it on the Sampler’s Check List.
4.16 Check the following points during sampling of the material: –
4.16.1 Mode of packing,
4.16.2 Indication of packing,
4.16.3 Details available on pack (Containers),
4.16.4 No. of packs (containers) received,
4.16.5 Total quantity received,
4.16.6 No. of packs (containers) sampled,
4.16.7 Quantity to be sampled.
4.16.8 Name of the person who sampled along with date of sampling.



4.17 Withdraw the samples randomly by opening different containers / Boxes as per ROOT N +1 and take out sampling quantity for visual inspection as per sampling plan
4.18 Note down the sampled quantity in Sampler’s checklist based on the number of packages to be sampled.
4.19 Examine the sampled material as per AQL against the approved standard for general appearance, deviation from normal visual quality, colour, text etc. wherever applicable.
4.20 Record the results in approved Visual Inspection Report for Aluminium foil and PVC Foil.
4.21 After completion of sampling the material pack shall be resealed with BOPP Tape or tied with the help of cable – tie.
4.22 Affix the “UNDER TEST” refer Annexure – 4. To all the rolls of sticker labels, foils and every container of rubber plugs.

For all other packaging materials at least one “UNDER TEST” Label shall be affixed on bottom container/ pack of each pallet.
4.23 Affix the SAMPLED BY QC sticker label duly signed and mentioning the container number according to sampling plan,



on outer container of the material from which sample is taken.
4.24 Check that the number of packs is correct as mentioned in under test label.
4.25 Take out composite sample for analysis as per respective Packing Material Specifications. Put the sampled quantity

in self-sealing polybag bearing the label of “SAMPLE FOR ANALYSIS”
4.26 Carry out testing of the packaging material as per the laid down specifications of respective material.
4.27 The sampling procedure described above will not be applicable for Tertiary Packaging material like Shipper,

pad, partition and corrugated trays. For these materials only one unit shall be collected and carry out the analysis as per laid down specification.

5.0 REASON FOR REVISION:

SOP is revised to incorporate detailed sampling procedure as per AQL and incorporation of Packaging material inward register.

6.0 TRAINING:

Trainer — Executive – QA

7.0 DISTRIBUTION:

Certified Copy No. 1 : Head of Department – Quality Control
Certified Copy No. 2 : File Copy for Packaging Department
Certified Copy No. 3 : Head – PLANT OPERATIONS
Original Copy : Head – QUALITY ASSURANCE

8.0 ANNEXURES:

Annexure – 1 : Format for Packaging Material Register

9.0 REFERENCE:

In-house.

 

 

SOP for testing of ETP water

sop for Calibration and Maintenance of Laboratory Instruments and Equipment

Disposal of Residual Sample or Left Over Material

sop for for Laboratory Incident

standard operating procedure temperature monitoring

sop for drying of silica gel

sop for operation of infrared moisture balance

sop for preparation of mobile phase

sop for treated RO water

sop for Preparation and Issuance of Analysis protocol standard

sop of placebo and impurity stock solutions

sop for disposal of residual sample  

sop for handling of pharmacopoeial changes

sop for procedure for operation of ultrasonic cleaner

difference between UPLC and HPLC

sop for for Emergency Eyewash and Shower

sop for operation and calibration of total organic carbon analyzers

sop for operation of cobb tester

sop for Operation and calibration of atomic absorption spectrophotometer

sop for Operation and calibration of gas liquid chromatograph

sop for operation of humidity oven

sop for operation and calibration of serological water bath

sop for monitoring of drain trap

sop for destruction of analytical samples after testing and control samples

sop for destruction of used chemicals

Sop for Operation of suction pump

sop for Operation and calibration uv cabinet

sop for Operation and calibration of bulk density apparatus

sop for operation and calibration of shore hardness tester

sop for operation of rub proofness tester

sop for monitoring of purified water

sop for Retesting of packaging materials

sop for Retesting and resampling of raw materials

sop for Control of issuance of record of analysis green sheets

sop for Control of computer passwords

sop for sampling of packaging materials PM

sop for sampling of sterile raw material

sop for sampling of intermediates and finished products

sop for operation and calibration of friability test apparatus

sop for approval and rejection of packaging materials

sop for non conformance of RM PM and finished product

sop for collection storage and disposal of control samples

sop for trend analysis of finished products

sop for Chromatographic practices and system suitability

SOP For Good Laboratory Practices

sop for cleaning and operation of sieve shaker

general specification of packing material cartons

sop for Password for Analytical Instrument and LIMS software

sop for Rounding off numerical analytical results

sop for sampling of bulk and finished product

sop for cleaning of spillage material

sop for Handling of Reference Standard

sop for hplc column maintenance and washing

procedure for sampling and handling of bulk sample

STP for borewell generation point (raw water storage tank)

sop for preparation and standardization of 0.1M Zinc Sulphate

Operation &calibration of analytical balance (dhona)

Operation and Calibration Procedure for Disintegration Test apparatus

sop for preparation and standardization of 1 M Hydrochloric Acid

Preparation and standardization of 0.1 M ceric ammonium sulphate solution

sop for preparation and standardization of 0.05 m iodine solution

validation of volumetric solution 0.1m ammonium thiocyanate

handling of reference standard and preparation of working standard

sop for water sampling and analysis

sop for operation for validation of excel worksheets

sop for laboratory cleaning

sop for stability of volumetric solutions

sop for preparation of raw material in process finish product packing material data sheets

sop for handling of hazardous chemicals

sop for handling of glassware and allocation of identification number

sop for operation cleaning and calibration of bursting strength tester

sop for rounding off the analytical test results

procedure for Analyst Qualification

sop for operation and calibration of dissolution Apparatus

procedure for maintenance of desiccators

sop for for hplc column receipt checking id no and regeneration

safety data sheet for laboratory chemicals

procedure for handling of poisonous chemicals

sop for cleaning of sampling devices

sop for calibration procedure of instruments

sop for specification and standard testing raw material packing material and finished product

procedure for operation and calibration of potentiometric titrator

procedure for operating and calibration of digital hardness tester

procedure for disposal of expired chemicals, reagents and solvents

sop for behavior in quality control department

sop for preparation and standardization 0.1M sodium thiosulphate

sop for preparation and standardization 0.1M Disodium Edetate

preparation and standardization 0.1M Sodium Hydroxide Solution

Preparation and standardization of 0.1M Perchloric acid solution

sop for preparation 0.05M edetate disodium

sop for preparation 0.1M silver nitrate

sop for Operation and Calibration of High Performance Liquid Chromatography

sop for UV & Visible Spectrophotometer

procedure for Cleaning of laboratory glassware

Cleaning of Instrument, Instrument bench and surrounding area of Quality

Safety Precaution in Quality Control Department

Operation & Calibration of Analytical Balance

Calibration of Glassware in Quality Control Department

handling of samples received in Quality Control

Cleaning and Operation of Refrigerator

Operation, Cleaning and Calibration of water bath

Operation & Calibration of Refractometer

Operation and Cleaning of Centrifuge Apparatus

cleaning, operation & calibration of Vernier caliper

Calibration of Fourier Transform Infrared Spectrophotometer (FTIR)

Cleaning and operation of Moisture Analyzer

Cleaning & Operation of Vacuum pump in Quality Control Department

Operation and Calibration of Polarimeter

Cleaning and operation of Magnetic Stirrer

Cleaning Operation and Calibration of Melting Point

Operation Cleaning and Calibration of Muffle Furnance in Quality Control Department

procedure of operation and Cleaning of Sonicator

Operation Cleaning & Calibration of pH meter in Quality Control Department

Entry and Exit in Quality Control Department

Exit mobile version