sop for Cleaning of Wax Vessel
1.0 Objective
To lay down a procedure for cleaning of wax vessel.
2.0 Scope
This Standard Operating Procedure is applicable for cleaning of water vessel at abc company.
3.0 Responsibility
3.1 Operator / Manufacturing Chemist.
3.2 Production Manager.
4.0 Abbreviations and Definitions
SOP : Standard Operating Procedure
PE : Production External
SLS : Sodium Lauryl Sulphate
5.0 Procedure
5.1 Before Cleaning:
5.1.1 Ensure that all utilities are disconnected such as electricity, steam, water etc.
5.1.2 Ensure that all moving parts are properly covered.
5.1.3 Ensure that all gauges and meters, control panel, sensors, motors etc are properly
covered and removable parts are removed.
5.1.4 Ensure that in sensitive places dry cleaning is done.
5.1.5 Prepare 10 liter 2.5% SLS solution (dissolve 0.250 kg SLS in 10 liter raw water.
5.2 Cleaning:
5.2.1 First wash all S.S. parts of the water vessel with raw water.
5.2.2 Scrap all the edges of the vessel with non particle spreading material.
5.2.3 Ensure that there is nothing except water inside the vessel.
5.2.4 Start the agitator.
5.2.5 Run for 5 minutes
5.2.6 Open the bottom valve.
5.3 First Wash
5.3.1 First wash all S.S. parts of the ointment manufacturing vessel with raw water.
5.3.2 Scrap all the edges of the vessel with non particle spreading material.
5.3.3 Ensure that there is nothing except water inside the vessel.
5.3.4 Start the agitator.
5.3.5 Run for 5 minutes.
5.3.6 Open the bottom valve.
5.3.7 Start the inline homogenizer and recalculates the water into the ointment manufacturing vessel.
5.3.8 After running the inline homogenizer for 5 minutes, stop the homogenizer and then close
the Bypass valves in the pipeline.
5.3.9 After that open the bottom outlet valve of the ointment manufacturing vessel and drain out
the water with main drain pipeline of the cleaning pipeline.
5.4 Second Wash
5.4.1 First wash all S.S. parts of the water vessel with 2.5% SLS solution.
5.4.2 Scrap all the edges of vessel with non particle spreading material.
5.4.3 Ensure that there is nothing except SLS solution inside the vessel.
5.4.4 Start the agitator.
5.4.5 Run for 5 minutes.
5.4.6 After that open the bottom outlet valve of the wax vessel and drain out the
SLS solution with main drain pipeline of the cleaning pipeline.
5.5 Third Wash
5.5.1 The third wash is with DM water.
5.5.2 The procedure is to be repeated in the above sequence.
5.5.3 Send the sample to Q.C. for wash water analysis and after getting approval
from Q.C. the label it as ‘CLEANED’.
6.0 Forms and Records
6.1 None
7.0 Distribution
7.1 Master Copy – Documentation Cell (Quality Assurance)
7.2 Controlled Copy – Production Department
8.0 History
Revision Number | Details For Change |
Reason for Revision |
00 | New SOP | NA |
sop for operation and cleaning of Hand coder
sop for Cleaning and Handling and Silicone Tubes
sop on operation and cleaning of coating pan
sop for Operation of cleaning of pipe lines
sop for operation of capsule loading machine semi automatic
sop for Machine operation capsule inspection and polishing machine
Sop batch demarcation and batch coding
sop for monitoring of reprocessing of products
sop for in-process control on liquids orals
sop for in process controls on tablets capsules packaging line
sop for Issuance retrieval and destruction of BMR and analytical records
sop for in process controls during granulation compression coating inspection
sop for Cleaning of Blister packing machine
sop for cleaning of dust exhausts
Entry Exit and Gowning Procedure in Dispensing Area
sop for Receipt and Storage of Raw Materials
sop for Verification of Weighing Balances
Opening And Closing Of The Capsule Department
Startup and close down procedure of manufacturing area
sop for Cleaning of Water Vessel
sop for Cleaning of Wax Vessel