Determination Of Diameter Width and Length

Determination Of Diameter Width and Length

 

1.0 Purpose
1.1 This procedure is applicable to all incoming all In-process and finished Products of tablets.

2.0 Apparatus
2.1 Vernier Calipers
3.0 Reagents
3.1 Nil
4.0 Procedure

4.1 Ensure the instrument/Vernier Calipers are clear and calibrated.
4.2 Switch on the instrument using green button.
4.3 Bring the jars together so that is no gap/they touch each other.
4.4 Then set for “0.00mm” using yellow (Zero) button.
4.5 Keep the sample to be tested between the jaws and hold it tightly. Then note down the reading shown in display.
4.6 Perform the test for 10 tablets to measure thickness for diameter, width and length of tablets.
4.7 The Diameter, width & Length reading shall be expressed in mm.
4.8 Report the range of the measurement observed.
4.9 Switch off the equipment and clear it with dry cloth.
4.10 The acceptance limits are given specification.
5.0 Reference
5.1 None
6.0 Revision History

 

  • Revision History
Revision No. Details of Changes Reason for change
00 New GTP NA

Standard testing procedure of Iron Sucrose Injection

Standard testing procedure lactose

Standard testing procedure mefenamic acid

standard testing procedure domperidone

standard testing procedure flavour mixed fruit

standard testing procedure dicyclomine hydrochloride

Standard testing procedure honey pure

standard testing procedure dextromethorphan hydrobromide

standard procedure of levocarnitine injection

Analysis of Ivermectin Suspension

standard testing procedure artemether injection

standard testing procedure artemether injection

standard testing procedure Carbocisteine syrup

standard testing procedure Phytomenadione injection

standard testing procedure serratiopeptidase



standard testing procedure starch IP

standard testing procedure sucrose refined sugar

standard testing procedure titanium dioxide

standard testing procedure tramadol hydrochloride

standard testing procedure zinc sulphate

standard testing procedure croscarmellose sodium

standard testing procedure colour erythrosine supra

standard testing procedure magnesium hydroxide

standard testing procedure diclofenac sodium

standard testing procedure dibasic calcium phosphate

standard testing procedure cyanocobalamin

standard testing procedure cholecalciferol

standard testing procedure Calcium carbonate oyster shell powder

standard test procedure Calcium Citrate

standard testing procedure Bronopol

standard testing procedure Bromhexine Hydrochloride

Standard Testing Procedure diclofenac sodium injection

Standard Testing Procedure Drotaverine Hydrochloride injection

analysis of Procyclidine HCl 5 mg Tablet

analysis of silodosin 8 mg capsule

Method of Analysis Ceftriaxone and Sulbactam For Injection

Analysis of Glimepiride and Metformin Hydrochloride (SR) Tablets

General Test Procedure Melting Range and Freezing Point

General Test Procedure Weight per ML and Specific Gravity

General Test Procedure Distillation Range

General Test Procedure Non Volatile Matter and Residue on Evaporation

General Test Procedure Clarity of Solution

General Test Procedure Limit Test Chloride

General Test Procedure Limit Test Iron

General Test Procedure Limit Test Heavy Metals

General Test Procedure Water Soluble Substances

General Test Procedure Acid Soluble Substances

General Test Procedure 0.1M Ammonium Thiocyanate

General Test Procedure 0.1M Ethanolic Sodium Hydroxide

Determination Of Diameter Width and Length

 

Leave a Comment

error: Content is protected !!