job responsibilities of quality control manager

 

 

job responsibilities of quality control manager

1) To ensure the compliance of current Good laboratory practices and standard operating procedures in
trendy working techniques in the pleasant control Laboratory. The Quality Control Laboratory.

2) To ensure the testing, approval or rejection of all Raw-materials, packing materials, Bulk Finished &
Finished products.

3) To review and updating of all SOPs as per requirements of cGLP on regular basis.

4) To train and develop all QC staff on cGLP advanced analytical technique and their evaluation on
Periodical basis.

5) To participate in execution of all validation program like process validation, cleaning validation etc.

6) To ensure the operation and calibration of all analytical instruments as per laid down procedures.



7) To ensure the proper documentation of all analysis including raw data, checking of all data and proper
Storage of data.

8) To organize the analysis of all stability samples, as per specified schedule (accelerated condition as
Well as controlled temperature).

9) To review and updating of all standard test procedures and specifications of all Raw-materials,
Packaging materials and Finished products on regular basis to meet regulatory requirements.

10) To ensure the proper management of references and working standards for accuracy of analytical data.

11) To ensure the proper standardization of volumetric solution, preparation of reagents and its
Documentation.

12) To develop the new analytical method and standard operating procedures (SOPs) for in-house or
Pharmacopoeia methods and prepare the method validation report.

13) To extend the support to regulatory affairs in preparing the analytical data as per their requirements
For registration of products in different countries.

14) To participate in the internal audits and vendor audits as per audit programs.

15) To organize the analysis of microbial samples, as per specified procedure and SOP training for
Microbiology laboratory

16) Preparation of SOP

17) Environmental Monitoring in Controlled and Critical Area by using different techniques such as
Settle Plate, Active Air Sampling, Surface monitoring and Personnel monitoring.

18) Revival of MTCC culture and handling, Culture quantification, Growth promoting test and
Environment isolates

19) Microbiological analysis in raw material, finished product as liquid Capsule Tablets.
Microbial Analysis of Raw water, in process and Purified water by different method

20) Actively Participate in validation process like (Autoclave, LAF, Area, HVAC, Water, Media fill.)



21) Sterility Test (Membrane Filtration Method)

22) Bacterial Endotoxin Test

23) Microbial Limit Test

24) Trend data of water and EM testing

Remarks: In absence of following person/s shall be responsible for carrying out routine functions:

Signature / Date Signature /Date
(Employee) (Department Head / Chief Executive Officer)

SOP for testing of ETP water

sop for Calibration and Maintenance of Laboratory Instruments and Equipment

Disposal of Residual Sample or Left Over Material

sop for for Laboratory Incident

standard operating procedure temperature monitoring

sop for drying of silica gel

sop for operation of infrared moisture balance

sop for preparation of mobile phase

sop for treated RO water

sop for Preparation and Issuance of Analysis protocol standard

sop of placebo and impurity stock solutions

sop for disposal of residual sample  

sop for handling of pharmacopoeial changes

sop for procedure for operation of ultrasonic cleaner

difference between UPLC and HPLC

sop for for Emergency Eyewash and Shower

sop for operation and calibration of total organic carbon analyzers

sop for operation of cobb tester

sop for Operation and calibration of atomic absorption spectrophotometer

sop for Operation and calibration of gas liquid chromatograph

sop for operation of humidity oven

sop for operation and calibration of serological water bath

sop for monitoring of drain trap

sop for destruction of analytical samples after testing and control samples

sop for destruction of used chemicals

Sop for Operation of suction pump

sop for Operation and calibration uv cabinet

sop for Operation and calibration of bulk density apparatus

sop for operation and calibration of shore hardness tester

sop for operation of rub proofness tester

sop for monitoring of purified water

sop for Retesting of packaging materials

sop for Retesting and resampling of raw materials

sop for Control of issuance of record of analysis green sheets

sop for Control of computer passwords

sop for sampling of packaging materials PM

sop for sampling of sterile raw material

sop for sampling of intermediates and finished products

sop for operation and calibration of friability test apparatus

sop for approval and rejection of packaging materials

sop for non conformance of RM PM and finished product

sop for collection storage and disposal of control samples

sop for trend analysis of finished products

sop for Chromatographic practices and system suitability

SOP For Good Laboratory Practices

sop for cleaning and operation of sieve shaker

general specification of packing material cartons

sop for Password for Analytical Instrument and LIMS software

sop for Rounding off numerical analytical results

sop for sampling of bulk and finished product

sop for cleaning of spillage material

sop for Handling of Reference Standard

sop for hplc column maintenance and washing

procedure for sampling and handling of bulk sample

STP for borewell generation point (raw water storage tank)

sop for preparation and standardization of 0.1M Zinc Sulphate

Operation &calibration of analytical balance (dhona)

Operation and Calibration Procedure for Disintegration Test apparatus

sop for preparation and standardization of 1 M Hydrochloric Acid

Preparation and standardization of 0.1 M ceric ammonium sulphate solution

sop for preparation and standardization of 0.05 m iodine solution

validation of volumetric solution 0.1m ammonium thiocyanate

handling of reference standard and preparation of working standard

sop for water sampling and analysis

sop for operation for validation of excel worksheets

sop for laboratory cleaning

sop for stability of volumetric solutions

sop for preparation of raw material in process finish product packing material data sheets

sop for handling of hazardous chemicals

sop for handling of glassware and allocation of identification number

sop for operation cleaning and calibration of bursting strength tester

sop for rounding off the analytical test results

procedure for Analyst Qualification

sop for operation and calibration of dissolution Apparatus

procedure for maintenance of desiccators

sop for for hplc column receipt checking id no and regeneration

safety data sheet for laboratory chemicals

procedure for handling of poisonous chemicals

sop for cleaning of sampling devices

sop for calibration procedure of instruments

sop for specification and standard testing raw material packing material and finished product

procedure for operation and calibration of potentiometric titrator

procedure for operating and calibration of digital hardness tester

procedure for disposal of expired chemicals, reagents and solvents

sop for behavior in quality control department

sop for preparation and standardization 0.1M sodium thiosulphate

sop for preparation and standardization 0.1M Disodium Edetate

preparation and standardization 0.1M Sodium Hydroxide Solution

Preparation and standardization of 0.1M Perchloric acid solution

sop for preparation 0.05M edetate disodium

sop for preparation 0.1M silver nitrate

sop for Operation and Calibration of High Performance Liquid Chromatography

sop for UV & Visible Spectrophotometer

procedure for Cleaning of laboratory glassware

Cleaning of Instrument, Instrument bench and surrounding area of Quality

Safety Precaution in Quality Control Department

Operation & Calibration of Analytical Balance

Calibration of Glassware in Quality Control Department

handling of samples received in Quality Control

Cleaning and Operation of Refrigerator

Operation, Cleaning and Calibration of water bath

Operation & Calibration of Refractometer

Operation and Cleaning of Centrifuge Apparatus

cleaning, operation & calibration of Vernier caliper

Calibration of Fourier Transform Infrared Spectrophotometer (FTIR)

Cleaning and operation of Moisture Analyzer

Cleaning & Operation of Vacuum pump in Quality Control Department

Operation cleaning and calibration of Karl Fischer Apparatus

Operation and Calibration of Polarimeter

Cleaning and operation of Magnetic Stirrer

Cleaning Operation and Calibration of Melting Point

Operation Cleaning and Calibration of Muffle Furnance in Quality Control Department

procedure of operation and Cleaning of Sonicator

Operation Cleaning & Calibration of pH meter in Quality Control Department

Entry and Exit in Quality Control Department

 

Leave a Comment

error: Content is protected !!