Site icon Pharma Dekho

sop for cleaning and assembly of compression machine

 

sop for cleaning and assembly of compression machine

PROCEDURE
As soon as the compression of a particular batch is over, clean the entire exterior of the machine as well as the room. Following procedure will be adhered to:
(1) Disconnect the electric supply
(ii) Dismantle carefully the following parts
• Feed hoppers
• Acrylic guards
• Feed-frames
• Turret guards
• Cover plate of the worn shaft
• Nylon break plugs along the spring steel strips
• Die screws
• Tablets collecting chutes
• Dust collecting hood assemblies (4 Nos.)
Clean all the above mentioned parts along with relevant bolts thoroughly with hot tap water and keep them aside.
a. Remove carefully all the lower punches by removing the plug and keep these punches in a
specially designed wooden tray, serially arranged. Similarly remove keep them in a separate
wooden tray serially arranged. Remove all the SS rod and keep them serially arranged in one of
the above trays. the upper punches and dies with the help of a



b. Clean all the interior areas of the machine like base plate on which the turret is fitted, cam
tracks, die seats, upper and lower punch holes, turret surface, first with a dry nylon brush and
then with special denatured spirit. Care should be taken while cleaning the punch hole and die
seats so that they are free from any particulate matter.

C. Wipe clean the exterior of the machine with a lint free duster soaked in special denatured spirit.

d. Get the entire area cleaned by the Janitor.

e. Cleaning and Fitting of Dies and Punches

Take about 2 liters of hot tap water, 10% Teepol (non toxic detergent solution) mixture and
clean all the punches dipping hot water Teepol mixture and then cleaning thoroughly
with hot tap water. After cleaning, all the punches and dies should be put serially in the clean
wooden trays meant for storing them.

f. Use 15 litres of distilled water to give couple of washes to the cleaned parts and the dismantled
punches and dies. Inspect the final rinse water for absence of any suspended matter. If
required, use additional distilled before cleaning the rinse water.

g. Wipe all the cleaned parts from Step f’ with a clean dry lint free cloth.

FITTING OF DIES
Before the dies are fitted, ensure all the die seats are free from any foreign matter. Place the die
face downwards on the die hole. Apply light pressure with fingers on the top phase of the die to
locate centrally over the die hole. After locating the die correctly, drive the die into its position
with the help of SS rod introduced through the upper punch guide holes. Once the die is fitted,
the top portion of the die should flush with the turret surface. Now introduce all the die screws
and tighten again. Check whether the die surfaces flush with the turret surface.

FITTING OF LOWER PUNCHES
Take a lower punch, wipe it dry, through the lower punch die hole taking care that each numbered punch goes into its corresponding compression station. All the lower punches thus introduced should move freely up and down. Put the plug back into its position. Fix all the cleaned and dried nylon plugs with spring steel strips.



FITTING OF UPPER PUNCHES
The cleaned and dried upper punches should be smeared with liquid paraffin and introduced into their corresponding holes.
Put back all the turret guards after wiping them dry. Fit the cleaned and dried feed frame at their
respective positions. Install the cleaned and dried acrylic guards and hoppers in their relevant
positions.

Assemble the cleaned dust collecting hood assemblies.

Cover the cleaned machine with a clean cloth cover. Affix a cleaning ticket indicating the
following:

• Equipment/Machine
• Last Product-
• Lot No.-
• Cleaned and ready for Product –
• Cleaned by
• Date
• Supervisor’s Signature

sop for post cleaning after media fill

sop for cip of mixing vessel mixing mobile vessel and holding vessel

sop for De-Bagging of Three Piece Vial Dropper Caps

sop for calibration and verification of check weigher

sop for Batch number and Manufacturing and Expiry Date Coding System

sop for Sanitization of Seals

standard operating procedure machine history file

sop for operation and cleaning of Hand coder

sop for Cleaning and Handling and Silicone Tubes

sop on operation and cleaning of coating pan

sop for Operation of cleaning of pipe lines

Sop for equipment assembly

sop for operation of capsule loading machine semi automatic

sop for Machine operation capsule inspection and polishing machine

Sop for issue of material

Sop batch demarcation and batch coding

sop for material receipts

sop for monitoring of reprocessing of products

sop for in-process control on liquids orals

sop for in process controls on tablets capsules packaging line

sop for Issuance retrieval and destruction of BMR and analytical records

sop for in process controls during granulation compression coating inspection

sop for Cleaning of Blister packing machine

sop for for charge hand over between the shifts

Performance requalification report of visual inspectors

sop for Cleaning and operation of ROPP caps inspection table

sop for usage and destruction of filter pad and cartridge filter

sop for cleaning and storage of transfer pipe

sop for Cleaning and operation of labeling machine

Cleaning and operation of the mono block filling and sealing machine

sop for Cleaning and operation of empty bottle inspection table

sop for Cleaning and operation of filter press

sop for cleaning and operation of liquid transfer pump and line

sop for cleaning and operation of storage vessels

sop for cleaning and operation of sugar syrup manufacturing vessel

sop for cleaning issuance and retrieval of accessories and change parts

sop for Cleaning and operation of visual inspection conveyor belt

sop for Cleaning and operation of spray gun and assemble

procedure for cleaning of Multimill

sop for cleaning and assembly of compression machine

sop for checking punch height

 

 

Exit mobile version