sop for Cleaning of Blister packing machine

 

 

sop for Cleaning of Blister packing machine

 

1.0 OBJECTIVE :
• To lay down a procedure for Cleaning of Blister packing machine
2.0 SCOPE :
• This procedure is applicable for Cleaning of Blister packing machine for production

3.0 RESPONSIBILITY:

• Operator – To perform the procedure. Head Officer
• Production: Officer /
• Production: To ensure that the operation is being performed in compliance with the
SOP.

4.0 PROCEDURE:
4.1 TYPE I CLEANING

(Change over from one batch to next batch of the same product, same potency and of similar product with ascending potency provided the color is same.)

 

• Ensure that all the materials of previous batch are removed from the blister-packing cubicle.
• Ensure that the power supply and compressed air supply are put off.
• Replace the ‘under process’ status label by ‘to be cleaned’ status label then ‘under cleaning’ Label while beginning the cleaning procedure.
• Clean the machine with dry lint free cloth.
• Clean the forming upper & lower platen, hopper, linear vibrator feeder part, Upper & lower sealing platen, embossing tool, perforation tool, punching tools, acrylic cover and guards with a dry lint free cloth.
• Affix the “cleaned” label on the machine with date and sign of the production officer as per SOP.
• Record the Start time and end time of cleaning in equipment usage log book and Clean the area as per SOP.
• Maintain The Type I Cleaning Checklist As Per Annexure I.
4.2 TYPE II CLEANING
(During changeover of product with different actives/color/descending potency or after maintenance of contact parts.)
• Replace the ‘under process’ status label by ‘to be cleaned’ status label then ‘under cleaning’ while starting the cleaning procedure.
• Ensure that the power supply and compressed air supply are turned off.
• Product contact parts like upper forming platen to be clean with nylon brush when cool, to eliminate any collected deposit on the surface of the platens. Use 70% IPA for the removal of adhered dried PVC.
• Clean the hopper/linear vibrating parts with lint free cloth dipped in purified water and then followed by dry lint free cloth.
• Remove entire change part assembly from the basic feeder unit. Wash the assembly with purified water and dry with lint free cloth and then reassemble it.
• Clean the sealing plate with Copper wire brush if the knurling has been stopped.
• Ensure cleaning of Embossing tool, perforation tool, punching tool shall be clean by dry lint free cloth before and after every batch.
• Acrylic covers and guards shall clean with Teepol followed by purified water and dry with lint free cloth. Dry the cleaned parts with a dry lint free cloth.
• Wipe the destroyed parts with 70% v/v IPA solution.
• Clean the internal and external surface of the machine, control panel and utility lines with a dry lint free cloth. Clean the machine with 70% v/v IPA solution.
• Reassemble the cleaned hopper, channel and hopper lid.
• Affix the ‘cleaned’ status label with date and sign of the production officer.
• Record the Start time and end time of cleaning in equipment usage log book and clean the area as per SOP No.
• Maintain the Type ‘II’ Cleaning As Per Annexure II.

5.0 ABBREVIATION (S):
• PVC : Poly vinyl chloride
• v/v : Volume/ Volume
• IPA : Isopropyl alcohol
• QC : Quality Control
• IPA : Isopropyl alcohol

Online Rejection in parenteral

Receipt of Batch from Production to Packing Department

sop for for Spillage Handling in parenteral area

sop for calibration of vessels with dipstick

sop for Cleaning of Bins and Containers

cip of mixing vessel and holding vessel

SOP FOR BATCH MANUFACTURING

sop for placebo batch

sop for Cleaning of Ampoule Filling and Sealing Machine

sop for Fogging in Sterile and Non Sterile Area

sop for for Filtration of Bulk Solution

sop for fumigation in production area

sop for post cleaning after media fill

sop for cip of mixing vessel mixing mobile vessel and holding vessel

sop for De-Bagging of Three Piece Vial Dropper Caps

sop for calibration and verification of check weigher

sop for Batch number and Manufacturing and Expiry Date Coding System

sop for Sanitization of Seals

standard operating procedure machine history file

sop for operation and cleaning of Hand coder

sop for Cleaning and Handling and Silicone Tubes

sop on operation and cleaning of coating pan

sop for Operation of cleaning of pipe lines

Sop for equipment assembly

sop for operation of capsule loading machine semi automatic

sop for Machine operation capsule inspection and polishing machine

Sop for issue of material

Sop batch demarcation and batch coding

sop for material receipts

sop for monitoring of reprocessing of products

sop for in-process control on liquids orals

sop for in process controls on tablets capsules packaging line

sop for Issuance retrieval and destruction of BMR and analytical records

sop for in process controls during granulation compression coating inspection

sop for Cleaning of Blister packing machine

sop for for charge hand over between the shifts

Performance requalification report of visual inspectors

sop for Cleaning and operation of ROPP caps inspection table

sop for usage and destruction of filter pad and cartridge filter

sop for cleaning and storage of transfer pipe

sop for Cleaning and operation of labeling machine

Cleaning and operation of the mono block filling and sealing machine

sop for Cleaning and operation of empty bottle inspection table

sop for Cleaning and operation of filter press

sop for cleaning and operation of liquid transfer pump and line

sop for cleaning and operation of storage vessels

sop for cleaning and operation of sugar syrup manufacturing vessel

sop for cleaning issuance and retrieval of accessories and change parts

sop for Cleaning and operation of visual inspection conveyor belt

sop for Cleaning and operation of spray gun and assemble

sop for Fogging in Aseptic and Non Aseptic Area

Leave a Comment

error: Content is protected !!