Microbial Monitoring by Plate Exposure

 

Microbial Monitoring by Plate Exposure

 

1.0 Objective
To lay down a procedure for Microbial Monitoring by Plate Exposure.
2.0 Scope
This Standard Operating Procedure is applicable for the Microbial Monitoring by Plate Exposure in TAC,

External and Liquid and Microbiology Lab of abc company.
3.0 Responsibility
3.1 Officer / Executive Quality Control Department are responsible for Microbial Monitoring by

Plate Exposure in TAC, DPI, Liquid and Lozenges and Microbiology Lab.
3.2 Head Quality Control is responsible for the compliance of this SOP.
4.0 Abbreviations and Definitions
SOP : Standard Operating Procedure
QC : Quality Control
TAC : Tablet and capsule block.
D.P. : Drain point
M.L.T. : Microbial limit Test
5.0 Procedure
5.1 For Passive air monitoring
5.1.1 Prepare the required quantity of SCDA media, Sterilize by autoclaving and dispense the media into

required number of Petri plates (90 mm dia.) aseptically.
5.1.2 Keep the solidified plates inside the BOD incubator at 20 oC – 25 oC for 18-24 hours prior

subjecting them for plate exposure?
5.1.3 Before exposure operations, the required per-incubated Petri plates are checked for any microbial

growth. If any microbial growth is observed then immediately discard those Petri plates

having microbial contamination/growth.
5.1.4 If no growth is observed then each plate is marked with respective sampling location point

followed by the date of exposure with the help of pencil marker.
5.1.5 Carry the plates to the desired location for exposure in a cleaned SS container mopped with 70% IPA.
5.1.6 Solidified agar plates are exposed at respective locations by wearing Face mask, Hand gloves rinsed

with 70% IPA solution, Cap and Clean gown for Non sterile areas and for sterile areas the exposure is

done by following proper sterile gowning procedure.
5.1.7 Expose the media containing plate by carefully removing the cover lid of the plate and placing the

media plate on Cleaned SS Petri plate holder/butter paper.
5.1.8 Similarly expose all the Petri plates at their respective locations for 04 hours in sterile areas,

02hours in Non sterile areas and not less than 30 minutes under laminar air flow unit.

Plate exposure operations should be done one feet above the working bench.
5.1.9 After completing the exposure period, collect all the plates from their respective locations in

the same SS container and transfer the SS container to the microbiology laboratory.
5.1.10 Before transferring to microbiology laboratory, mop the outside of the SS container

with 70% IPA and then bring the container to the microbiology laboratory. Microbiologists

should handle the plates by wearing cleaned hand gloves only.
5.1.11 Collect all the exposed plates and unexposed plates in SS container and transfer in BOD

incubator at 20oC – 25oC for 72 hrs days and than incubate the plates by transferring them to

Incubator at 30 oC – 35 oC for the next remaining 48 hrs.
5.1.12 After Incubation counts the number of colonies for each plate representing a respective location.

Record the counts in a respective format.
5.1.13 Plate exposure operations are done once in fortnightly ± 2 days that may vary according to

company’s holiday and other occasions, for liquid block and TAC block of production areas

but this operation is followed during Filling or twice in a week if there is no activity, in sterile

areas of production areas and daily in Microbiology Area.
5.1.14 The alert and action limit of microbial counts for various departments is as follows on their report annexure.
5.2 For Active air monitoring
5.2.1 Sterilize the Stainless steel impaction head assembly as per SOP No.
5.2.2 Sanitize the whole body of the air sampler by mopping with 70% IPA.
5.2.3 Transfer the sterile media filled air sampling cassettes/plate as well as the air sampler to the sampling

location through pass box or change room in areas.
5.2.4 Set the Volume of air to be sampled to 1000 liters and then place the air sampling cassette/plate

on the plate holder of the instrument by removing the lid of the air sampling cassette/plate,

Close the agar cassette with sterilized perforated Stainless steel head adapter immediately;

adopting least exposure to the environment.
5.2.5 Place the Air sampler at the sampling location and start air sampling by pressing twice the

start key present on the operation panel of the equipment.
5.2.6 After air sampling period is over; remove sieve adapter assembly and replace air sampling

cassette lid immediately.
5.2.7 Proceed the air sampling operations in other specified sampling locations in a similar manner

after mopping the SS sieve with 70% of Isopropyl alcohol.
5.2.8 Collect all the sampled Petri plate and unsampled Petri plate (Negative) cassettes/plate inside a

clean IPA mopped SS container with lid and transfer the SS Container from sterile area to incubator

through the location.
5.2.9 Incubate all the plates first at 20 oC – 25 oC for 72 hrs. and followed by at 30o – 35 oC for 48 hrs.
5.2.10 Plate exposure operations are done once in fortnightly ± 2 days that may vary according to

company’s holiday and other occasions, for liquid block and Monthly± 2 days exposure in TAC

block areas but this operation is followed during Filling or twice in a week if there is no activity, in

sterile areas of production areas and daily in Microbiology Area.
5.2.11 After incubation count the number of colonies and report the number of Cfu per cubic meter

Record all the observations properly in controlled format.
5.2.12 Discard all the plates after observation as per SOP No.
5.2.13 Alert and action limits are given in respective annexure.

6.0 Forms and Records
6.1 Environmental Monitoring of Aseptic Area by Passive Air Sampling (Settle plate)- Annexure-1
6.2 Passive Air Sampling Record of Sterility Testing Area – Annexure-2
6.3 Passive Air Sampling Record of Microbiological Testing Area – Annexure-3
6.4 Liquid Manufacturing Area Passive Air Sampling Record – Annexure-4
6.5 Tablet and Capsule Manufacturing Area Passive Air Sampling Record – Annexure-5
6.6 Plate Exposure Schedule – Annexure-6
6.7 Active Air Sampling Record of Microbiological Testing Area – Annexure-7
6.8 Active Air Sampling Record of Sterility Testing Area – Annexure-8
6.9 Environmental Monitoring of Aseptic area By Active Air Sampling – Annexure-9
6.10 Tablet and Capsule Manufacturing Area Active Air Sampling Record – Annexure-10
6.11 Liquid Manufacturing Area Active Air Sampling Record – Annexure-11
7.0 Distribution
7.1 Master copy – Documentation Cell (Quality Assurance)
7.2 Control copy – Quality Control
8.0 History

Revision Number Details For Change
Reason for Revision
00 New SOP NA

sop for calibration and validation of micro autoclave

sop for Sterility failure investigation

cleaning and operation of discard autoclave

sop for operation of fogger machine

sop for Biological assay of lactic acid bacillus

sop for preparation of culture inoculum

STP for sterility testing of sterile gloves

sop for Operation and calibration of active air sampler

sop for transfer of material for testing and sampling in sterile area

entry & exit procedure in microbiology laboratory

Growth Promotion Test In Microbiology Laboratory

Operation of B.O.D in Microbiology Laboratory




Operation of Horizontal Laminar Air Flow in the microbiology laboratory

Operation and cleaning of Pass Box.

Operation and cleaning of air sampler

Cleaning and Sterilization of Glassware

Analysis of water for microbial load in microbiology lab

Operation and temperature monitoring of Refrigerator

Fumigation of Microbiology Laboratory.

Entry & Exit procedure In Sterility Area

SOP for Microbial analysis of Raw Material Finished Products

SOP for Operation & Calibration of pH meter in Micro Department

SOP for Operation & Calibration of pH meter in Micro Department

SOP Operation and calibration of Hot Air Oven In Microbiology

SOP for operation cleaning & calibration of Digital colony counter

SOP for Operation And Cleaning of Microscope

sop for Media Preparation and Consumption

sop for Receipt Storage and Usage of Culture Media

sop for Cleaning Sanitization And Disinfection In Microbiology

sop for Environmental monitoring of all the Classified area

sop for Handling and Sub culturing of Microbial cultures

sop for Media Growth Promotion Test and various Microbiological test

sop for BOD incubator operation and cleaning

sop sampling of water for microbiological analysis

sop for Disinfectant Efficacy Test

sop for for cleaning and operation of vortex mixture

sop for Temperature & Relative Humidity Monitoring

sop for Operation and Calibration of Heating Block

sop for Sterility Testing of Microbiology

sop for Disposal of Culture Media

sop for Drain point of Microbiology

sop for entry & exit procedure In Microbial limit test and Biosafety

sop for Gram Staining of Bacteria in Microbiology Laboratory

sop for Monitoring of Compressed Air/gases for microbiological analysis

sop for BET (Bacterial Endotoxin) test in Microbiology

sop for receipt storage and Determining the population of Biological indicators

sop for qualification of analyst microbiologist

sop for Bioburden test of Packing materials in Microbiology Laboratory

sop for microbiological assay of erythromycin antibiotic

sop for liquid particle counter

sop for operation and calibration of digital zone reader

sop for monitoring of ultraviolet efficiency LAF and pass box

microbiological assay of cyanocobalamin or vitamin B12

gowning procedure for microbiological testing area

swab testing of various surfaces for bioburden determination

sop for endotoxin challenge test

Hold time study protocol for sterilized media

sop for personnel Qualification protocol for aseptic area

sop for sampling and testing of drain water

Sop for Operation of Airborne Particle Counter

sop for Inoculum Preparation

sop for Validation protocol of steam sterilizer autoclave

sop for pathogen detection from drain point

Sop for Analysis of Raw water Purified water water for injection and pure steam water

sop for preservatives efficacy test

sop for collection and preservation of in house isolated microorganisms

sop for Operation Calibration and Maintenance of Micropipette

Sop for UV Efficacy Test

sop for gram staining

Sop for swab testing

sop for microbiological testing of water

PROCEDURE FOR FUMIGATION

sop for depyrogenation of apparatus

sop for media preparation

sop for fertility test growth promotion test of media

sop for Operation and cleaning of moist heat sterilizer

sop for monitoring by active air sampler

sop for swab sampling and testing for clean rooms in production area

sop for monitoring in microbiology laboratory

sop for Fumigation of aseptic area and microbiology lab

sop for monitoring of personnel in aseptic area

sop for maintenance of cultures

sop for Operation and cleaning of laminar bench

preparation of settle plates

sop for monitoring of pure steam

sop for entry and exit procedure to m.l.t and b.e.t room

sop for storage of and use of media

sop for disposal of microbiological media and cleaning of microbiological glassware

Preparation Filtration Usage and Destruction of Disinfectant Solution

Entry Exit and gowning Procedure in Microbiology Laboratory

Safety measures to be followed in microbiology laboratory

Growth Promotion Test of Media

Preservation and Maintenance of Microbial Strain

Entry and Exit in Microbiology Sterile Area

Entry and Exit in Microbiology Limit testing area

Water sampling of raw water purified water WFI and PSG in microbiology Lab

sop of Microbiological assay

Exit mobile version