entry and exit procedure in microbiology laboratory
1.0 OBJECTIVE
1.1 To lay down a procedure for entry & exit procedure in microbiology laboratory.
2.0 SCOPE
2.1 This procedure is applicable to all employees/staff/worker/visitor entry & exit from microbiology laboratory
3.0 RESPONSIBILITY
3.1 All employees/Visitor
4.0 ACCOUNTABILITY
4.1 QC Manager
5.0 PROCEDURE
5.1 Entry Procedure
5.2 First change room
5.2.1 Push the door and enter in 1st change room in microbiology section.
5.2.2 Wear out your street footwear and keep at designated place.
5.2.3 Pull the door and enter in 2nd change room.
5.3 Second change room
5.3.1 Sit on the cross over bench and swing his/her feet, to cross the cross over bench.
5.3.2 Open the door of Dress cabinet ,Take clean cap ,mask & Apron and wear it.
5.3.3 Wear, company foot wear from designated place.
5.3.4 Check your complete out fit in mirror.
5.3.5 Sanitize the hand with 70% IPA , pull the door and enter in the Microbiology lab.
5.4 PROCEDURE FOR VISITOR
5.4.1 Push the door and enter in to 1st change room.
5.4.2 Read and follow the direction for given in display SOP.
5.4.3 Enter in 2nd change room.
5.4.4 Sit on the cross over bench put on the shoe cover over shoe, ensure the while wear feet don’t touch the floor.
5.4.5 Swing your feet and cross over the bench.
5.4.6 Open the door (His/Her) of Dess cabinet, take clean cap mask & Apron for visitor and wear it.
5.4.7 Check his/her out fit in mirror
5.4.8 Sanitize hand with 70% IPA, pull door and enter in microbiology lab.
6.0 Exit procedure in Microbiology laboratory
6.1 Remove Apron & cap place in SS waste bin.
6.2 Remove footwear place in SS bench.
6.3 Sit on cross over bench & cross, wear own footwear who place in 2nd change room.
6.4 While wear own street foot wear than exit in microbiology laboratory.
6.1 Exit procedure for visitor
6.1.1 Visitor enter in 1st change room, cross the cross over bench & enter in change room 2n
6.1.2 Remove your mask & shoe cover place in ss bin, than remove cap or Apron place in other ss bin.
6.1.3 Then exit microbiology lab.
7.0 ABBREVIATIONS
Sr. No. | Abbreviation used | Extended Form |
1.0 | SOP | Standard Operating Procedure |
2.0 | QA | Quality Assurance |
3.0 | ML | Microbiology Lab |
4.0 | QC | Quality Control |
sop for calibration and validation of micro autoclave
sop for Sterility failure investigation
cleaning and operation of discard autoclave
sop for operation of fogger machine
sop for Biological assay of lactic acid bacillus
sop for preparation of culture inoculum
STP for sterility testing of sterile gloves
sop for Operation and calibration of active air sampler
sop for transfer of material for testing and sampling in sterile area
entry & exit procedure in microbiology laboratory
Growth Promotion Test In Microbiology Laboratory
Operation of B.O.D in Microbiology Laboratory
Operation of Horizontal Laminar Air Flow in the microbiology laboratory
Operation and cleaning of Pass Box.
Operation and cleaning of air sampler
Cleaning and Sterilization of Glassware
Analysis of water for microbial load in microbiology lab
Operation and temperature monitoring of Refrigerator
Fumigation of Microbiology Laboratory.
Entry & Exit procedure In Sterility Area
SOP for Microbial analysis of Raw Material Finished Products
SOP for Operation & Calibration of pH meter in Micro Department
SOP for Operation & Calibration of pH meter in Micro Department
SOP Operation and calibration of Hot Air Oven In Microbiology
SOP for operation cleaning & calibration of Digital colony counter
SOP for Operation And Cleaning of Microscope
sop for Media Preparation and Consumption
sop for Receipt Storage and Usage of Culture Media
sop for Cleaning Sanitization And Disinfection In Microbiology
sop for Environmental monitoring of all the Classified area
sop for Handling and Sub culturing of Microbial cultures
sop for Media Growth Promotion Test and various Microbiological test
sop for BOD incubator operation and cleaning
sop sampling of water for microbiological analysis
sop for Disinfectant Efficacy Test
sop for for cleaning and operation of vortex mixture
sop for Temperature & Relative Humidity Monitoring
sop for Operation and Calibration of Heating Block
sop for Sterility Testing of Microbiology
sop for Disposal of Culture Media
sop for Drain point of Microbiology
sop for entry & exit procedure In Microbial limit test and Biosafety
sop for Gram Staining of Bacteria in Microbiology Laboratory
sop for Monitoring of Compressed Air/gases for microbiological analysis
sop for BET (Bacterial Endotoxin) test in Microbiology
sop for receipt storage and Determining the population of Biological indicators
sop for qualification of analyst microbiologist
sop for Bioburden test of Packing materials in Microbiology Laboratory
sop for microbiological assay of erythromycin antibiotic
sop for liquid particle counter
sop for operation and calibration of digital zone reader
sop for monitoring of ultraviolet efficiency LAF and pass box
microbiological assay of cyanocobalamin or vitamin B12
gowning procedure for microbiological testing area
swab testing of various surfaces for bioburden determination
sop for endotoxin challenge test
Hold time study protocol for sterilized media
sop for personnel Qualification protocol for aseptic area
sop for sampling and testing of drain water
Sop for Operation of Airborne Particle Counter
sop for Validation protocol of steam sterilizer autoclave
sop for pathogen detection from drain point
Sop for Analysis of Raw water Purified water water for injection and pure steam water
sop for preservatives efficacy test
sop for collection and preservation of in house isolated microorganisms
sop for Operation Calibration and Maintenance of Micropipette
sop for microbiological testing of water
sop for depyrogenation of apparatus
sop for fertility test growth promotion test of media
sop for Operation and cleaning of moist heat sterilizer
sop for monitoring by active air sampler
sop for swab sampling and testing for clean rooms in production area
sop for monitoring in microbiology laboratory
sop for Fumigation of aseptic area and microbiology lab
sop for monitoring of personnel in aseptic area
sop for maintenance of cultures
sop for Operation and cleaning of laminar bench
sop for monitoring of pure steam
sop for entry and exit procedure to m.l.t and b.e.t room
sop for storage of and use of media
sop for disposal of microbiological media and cleaning of microbiological glassware