1.0 Objective
To lay down a procedure for disposal of used culture and used media.
2.0 Scope
This Standard Operating Procedure is applicable for disposal of used culture and used media to be followed at formulation plants of abc company.
3.0 Responsibility
3.1 Officer / Executive Quality Control Department are responsible for disposal of used culture and used media.
3.2 Head Quality control is responsible for the compliance of this SOP.
4.0 Abbreviations and Definitions
QC : Quality Control
IPA : Iso Propyl Alcohol
SOP : Standard Operating Procedure
No. : Number
LAF : Laminar Air Flow.
ETP : Effluent Treatment Plant
Min. : Minutes
5.0 Procedure
5.1 For Microbial Culture:
5.1.1 After each subculture, check the growth of the respective cultures after the recommended incubation period and if the growth is satisfactory, the earlier culture tube shall be disposed off.
5.1.2 After the requisite time period for the preservation of any culture is over, remove the culture tubes from the refrigerator.
5.1.3 Sterilize the culture tubes at 121 °C temperature for 30 Min.
5.1.4 After completion of sterilization cycle, wear hand gloves and remove the culture tubes from the autoclave.
5.1.5 Send autoclaved (decontaminated) content in liquid form to the ETP for disposal.
5.1.6 Remove any labels / markings on tube.
5.1.7 Dip the empty tubes in disinfectant for 30 minutes.
5.1.8 Wash the test tubes thoroughly in the running purified water.
5.2 For Culture Media Plates:
5.2.1 Place the entire Petri plate along with the media contents in a disposable bags or metal container.
5.2.2 Autoclave the container at 121°C for 30 minutes.
5.2.3 The distorted Petri plates are sent to the scrap yard and decontaminated media are sent to the ETP for disposal.
5.2.4 Dip the Petri plates in disinfectant for 30 minutes. Wash the Petri plates thoroughly in the running purified water.
5.3 For expired media:
5.3.1 Wear hand gloves and nose mask.
5.3.2 Remove the contents of the media container with the help of spatula into a bucket having purified water.
5.3.3 Dissolve the media in purified water properly and then transfer the contents in disposable bag or metallic container.
5.3.4 Autoclave the disposable bag/container at 121°C for 30 minutes.
5.3.5 Send autoclave (decontaminated) content to the ETP for disposal.
5.3.6 Maintain the Disposal record of used culture and used media in Used Media sterilization Record.
6.0 Forms and Records
6.1 Used Media Sterilization Record – Annexure-1
7.0 Distribution
7.1 Master copy – Documentation Cell (Quality Assurance)
7.2 Control copy – Quality Control
8.0 History

Revision Number Details For Change
Reason for Revision
00 New SOP NA

sop for calibration and validation of micro autoclave

sop for Sterility failure investigation

cleaning and operation of discard autoclave

sop for operation of fogger machine

sop for Biological assay of lactic acid bacillus

sop for preparation of culture inoculum

STP for sterility testing of sterile gloves

sop for Operation and calibration of active air sampler

sop for transfer of material for testing and sampling in sterile area

entry & exit procedure in microbiology laboratory

Growth Promotion Test In Microbiology Laboratory

Operation of B.O.D in Microbiology Laboratory

Operation of Horizontal Laminar Air Flow in the microbiology laboratory

Operation and cleaning of Pass Box.

Operation and cleaning of air sampler

Cleaning and Sterilization of Glassware

Analysis of water for microbial load in microbiology lab

Operation and temperature monitoring of Refrigerator

Fumigation of Microbiology Laboratory.

Entry & Exit procedure In Sterility Area

SOP for Microbial analysis of Raw Material Finished Products

SOP for Operation & Calibration of pH meter in Micro Department

SOP for Operation & Calibration of pH meter in Micro Department

SOP Operation and calibration of Hot Air Oven In Microbiology

SOP for operation cleaning & calibration of Digital colony counter

SOP for Operation And Cleaning of Microscope

sop for Media Preparation and Consumption

sop for Receipt Storage and Usage of Culture Media

sop for Cleaning Sanitization And Disinfection In Microbiology

sop for Environmental monitoring of all the Classified area

sop for Handling and Sub culturing of Microbial cultures

sop for Media Growth Promotion Test and various Microbiological test

sop for BOD incubator operation and cleaning

sop sampling of water for microbiological analysis

sop for Disinfectant Efficacy Test

sop for for cleaning and operation of vortex mixture

sop for Temperature & Relative Humidity Monitoring

sop for Operation and Calibration of Heating Block

sop for Sterility Testing of Microbiology

sop for Disposal of Culture Media

sop for Drain point of Microbiology

sop for entry & exit procedure In Microbial limit test and Biosafety

sop for Gram Staining of Bacteria in Microbiology Laboratory

sop for Monitoring of Compressed Air/gases for microbiological analysis

sop for BET (Bacterial Endotoxin) test in Microbiology

sop for receipt storage and Determining the population of Biological indicators

sop for qualification of analyst microbiologist

sop for Bioburden test of Packing materials in Microbiology Laboratory

sop for microbiological assay of erythromycin antibiotic

sop for liquid particle counter

sop for operation and calibration of digital zone reader

sop for monitoring of ultraviolet efficiency LAF and pass box

microbiological assay of cyanocobalamin or vitamin B12

gowning procedure for microbiological testing area

swab testing of various surfaces for bioburden determination

sop for endotoxin challenge test

Hold time study protocol for sterilized media

sop for personnel Qualification protocol for aseptic area

sop for sampling and testing of drain water

Sop for Operation of Airborne Particle Counter

sop for Inoculum Preparation

sop for Validation protocol of steam sterilizer autoclave

sop for pathogen detection from drain point

Sop for Analysis of Raw water Purified water water for injection and pure steam water

sop for preservatives efficacy test

sop for collection and preservation of in house isolated microorganisms

sop for Operation Calibration and Maintenance of Micropipette

Sop for UV Efficacy Test

sop for gram staining

Sop for swab testing

sop for microbiological testing of water

PROCEDURE FOR FUMIGATION

sop for depyrogenation of apparatus

sop for media preparation

sop for fertility test growth promotion test of media

sop for Operation and cleaning of moist heat sterilizer

sop for monitoring by active air sampler

sop for swab sampling and testing for clean rooms in production area

sop for monitoring in microbiology laboratory

sop for Fumigation of aseptic area and microbiology lab

sop for monitoring of personnel in aseptic area

sop for maintenance of cultures

sop for Operation and cleaning of laminar bench

preparation of settle plates

sop for monitoring of pure steam

sop for entry and exit procedure to m.l.t and b.e.t room

sop for storage of and use of media

sop for disposal of microbiological media and cleaning of microbiological glassware

Preparation Filtration Usage and Destruction of Disinfectant Solution

Entry Exit and gowning Procedure in Microbiology Laboratory

Safety measures to be followed in microbiology laboratory

 

 

Leave a Comment

error: Content is protected !!