sop for Preventive Maintenance Of Fluid Bed Dryer
1.0 Objective
To lay down a procedure for the Preventive Maintenance for the Fluid Bed Dryer.
2.0 Scope
This Standard Operating Procedure is applicable for the Preventive Maintenance of Fluid Bed Dryers to be followed at formulation plants
3.0 Responsibility
3.1 Engineering Officer / Executive shall be responsible for the execution of this procedure.
3.2 Engineering Manager shall be responsible for the implementation of this SOP.
3.3 Head QA/designee should be responsible for the compliance of this SOP.
4.0 Abbreviations and Definitions
SOP : Standard Operating Procedure etc
No : Number
QA : Quality assurance
Qty. : Quantity
FBD : Fluid bed dryer
ER : Engineering
5.0 Procedure
5.1 General Conditions
5.1.1 Refer the master plan of preventive maintenance.
5.1.2 Equipment shall be available for preventive maintenance.
5.1.3 Clean oil / grease stains & remove unwanted material, spares after completion of work.
5.2 Precautions
5.2.1 Use necessary safety wears, while doing the work.
5.2.2 Ensure covers & guards are properly fixed
5.3 Procedure For Preventive Maintenance Of Fluid Bed Dryer
5.3.1 Ensure that electrical supply is in off position in main panel and display “Under Maintenance” Board on the panel board and inform all the concerned.
5.3.2 Operator or above has to ensure and verify the check points for the preventive maintenance as shown in the annex – 1,2,3 & 4 of this SOP.
5.3.3 After the completion of preventive maintenance, check the machine for smooth operation.
5.3.4 Remove “Under Maintenance” Board on the panel board after completion of the Maintenance.
5.3.5 The operator / technician who perform the job will enter his name / sign in “Done By” Column and responsible Engineer/ Officer and Officer – Production will put sign in “Checked by” column.
5.3.6 Quarterly maintenance will include the jobs of monthly maintenance, half yearly Maintenance will include the jobs of monthly and quarterly maintenance and year Maintenance will include the jobs of monthly, quarterly, half yearly and Yearly Maintenance.
5.4 Monthly preventive maintenance is to be carried out as per the following check points:
5.4.1 Check and tight the foundation bolt of bottom body all exposed nut and bolts.
5.4.2 Clean the FBD filters as per respective SOP.
5.4.3 Check all the roller of product container trolley for any jam problem. Change the roller bearings, if needed.
5.4.4 Tighten all the electrical connections & clean the electrical panel with hand blower.
5.4.5 Check all pneumatic pipes and valves for any leakage of air, if found damaged, replace the same.
5.4.6 Check the filter bag-supporting hanger (hook) for any damage.
5.4.7 Check the supporting mounting bolt of lowering cylinder of filter bag housing.
5.4.8 Check all clamping bolts of ducting system (Inlet & Outlet ducting).
5.4.9 Check the motor terminal connections and tighten the same
5.4.10 Check all the clamps of product container and tight them, if required.
5.4.11 Check the following gasket for any damage: Gasket between retarding chamber & product container, Gasket for explosion flap, “O” ring for butterfly valve.
5.5 Quarterly preventive maintenance is to be carried out as per the following check points:
5.5.1 Check the filter bag shaking cylinder for any leakage of air. (If required, air seal is to be changed).
5.5.2 Check the pneumatic cylinder for any air leakage. (if required, replace pneumatic Cylinder piston “o” ring & sealing gasket).
5.5.3 Check & clean the steam strainers at inlet & outlet.
5.5.4 Check & clean the steam traps.
5.5.5 Check the proper Earthing.
5.6 Half yearly preventive maintenance is to be carried out as per the following check points:
5.6.1 Check and tighten the blower motor terminal connection.
5.6.2 Check the blower impeller for proper balancing.
5.6.3 Check the entire solenoid valve with coil. (If required, change the solenoid valve & coil).
5.7 Yearly preventive maintenance is to be carried out as per the following check points:
5.7.1 Check the main switch, fuse & switch contacts of test lines for continuity.
5.7.2 Check interlocking of process timer.
5.7.3 Check pressure relief flap.
5.7.4 Check all electrical connections (control panel, all motors,) for any loose Connections, burned contacts, signs of overheated wires, tighten/replace the same.
6.0 Forms and Records
6.1 Quarterly Preventive Maintenance Check List of Fluid Bed Dryer
6.2 Half Yearly Preventive Maintenance Check List of Fluid Bed Dryer
6.3 Yearly Preventive Maintenance Check List of Fluid Bed Dryer – Annexure-3
7.0 Distribution
7.1 Master copy – Documentation Cell (Quality Assurance)
7.2 Controlled copies – Engineering Department
1 | Before starting Preventive maintenance of FBD “switch off” the panel board. | Ok/Not Ok | ||
2 | Put the board of “Under Maintenance “ on the panel board | Ok/Not Ok | ||
3 | Check and tight the foundation bolt of bottom body all exposed nut and bolts. | Ok/Not Ok | ||
4 | Clean the FBD filters as per respective SOP. | Ok/Not Ok | ||
5 | Check all the roller of product container trolley for any jam problem. Change the roller bearings, if needed. | Ok / Not ok | ||
6 | Check all pneumatic pipes and valves for any leakage of air, if found damaged, replace. | Ok/Not Ok | ||
7 | Check the filter bag-supporting hanger (hook) for any damage. | Ok/Not Ok | ||
8 | Check the supporting mounting bolt of lowering cylinder of filter bag housing. | Ok/Not Ok | ||
9 | Check all clamping bolts of ducting system (Inlet & Outlet ducting). | Ok/Not Ok | ||
10 | Check the earthing connection of motor. | Ok/Not Ok | ||
11 | Check the all terminal connections and tighten the same | Ok/Not Ok | ||
12 | Check all the clamp of product container and tight them, if required | Ok/Not Ok | ||
13 | Check the following gasket for any damage: Gasket between retarding chamber & product container, Gasket for explosion flap,“O” ring for butterfly valve. | Ok/Not Ok | ||
14 | . Check the filter bag shaking cylinder for any leakage of air. (If required, air seal is to be changed). | Ok/Not Ok | ||
15 | Check the pneumatic cylinder for any air leakage. (If required, replace pneumatic Cylinder piston “O” ring & sealing gasket) | Ok/Not Ok | ||
16 | Check & clean the steam strainers and steam trap at inlet & outlet. | Ok/Not Ok | ||
17 | Clean the FBD filters as per respective SOP | Ok/Not Ok | ||
18 | Remove the board of “Under Maintenance” on the panel board | Ok/Not Ok |
sop for Execution of Preventive Maintenance
Preparation of Sodium Hydroxide Solution
sop for water cooled chiller operation
cleaning and preventive maintenance of LAF and RLAF
sop for replacement of water system filters
cleaning and preventive maintenance of insectocutor
sop for operation of preventive maintenance
sop for material receiving and consumption record
sop for Preventive maintenance of bottle washing machine
sop for Replacement of Battery of Electronic Devices
sop for Preparation of R.O. Antiscalant Solution
Preventive Maintenance of Rapid Cooling Steam Sterilizer
Preventive Maintenance of Rapid cooling steam Generator
sop for Preventive Maintenance of Dust Collector
sop for Replacement of HVAC filters
SOP for Battery Backup in Mobile Laminar Air Flow Trolley
sop for Replacement of Tube lights
sop for Replacement of UV light of purified water plant
sop for Cleaning of soft water storage tank and RO feed tank
sop for Preparation of Sodium hydroxide Solution
sop for Operation and regeneration of softener plant
Procedure Of Issuance Of material from Engineering Store
sop for Preventive Maintenance of Filter Press
sop for Preventive Maintenance of Sugar Transfer System
sop for Preventive Maintenance of Shrink Sleeve Machine
sop for Preventive Maintenance of ROPP Cap Elevator
sop for Preventive Maintenance of Liquid Transfer Pumps
sop for Preventive Maintenance of Liquid Tanks
Preventive Maintenance of Strip De-Foiling Machine
sop for Preventive Maintenance of Colloidal Mill
sop for Preventive Maintenance of Packing Collator Belt
sop for Checking light intensity
sop for Operation of Fire- Extinguisher
sop for Passivation of WFI Distribution Loop
sop for Analysis of Effluent Treatment Plant Water
sop for Methodology to Dispose ETP Sludge
sop for Action Plan In Case Of Electrical Power Failure
sop for Colour Coding of Piping and Accessories of Utilities
sop for Disposal of Engineering Waste
Filter Cleaning of HVAC System RLAF & LAF
Procedure for Calibration of Magnehelic Gauge
Procedure for Calibration of Vacuum Gauge
Procedure for Calibration of Pressure Gauge
sop for Procedure for Calibration of Temperature Controller
sop for Preventive Maintenance of Infrared Dryer Umbrella Type
sop for Preventive Maintenance of Battery stacker
sop for Preventive Maintenance of Lift
sop for Preventive Maintenance of Vacuum Cleaner
sop for Preventive Maintenance of laminar air flow unit
sop for Preventive Maintenance of Lozenges Manufacturing Line
sop for Preventive Maintenance of Garment Washing Machine
sop for Preventive Maintenance of Multi Column Distillation Plant
sop for Preventive Maintenance of Steam Sterilizer Autoclave
sop for Preventive Maintenance of Pure steam Generator
sop for Preventive maintenance of Depyrogenating Tunnel
sop for Preventive Maintenance of vial sealing machine
sop for preventive maintenance of Powder Filling and Rubber Stoppering machine
sop for Preventive Maintenance of Vial Washing Machine
sop for Preventive Maintenance of Inspection Table
sop for Preventive Maintenance of Hi-Cart
sop for Preventive Maintenance of Turn table
sop for Preventive Maintenance of sticker labeling machine
sop for Preventive Maintenance of Liquid Filling and Sealing Machine
sop for Preventive Maintenance of Linear Bottle Washing Machine
sop for Preventive Maintenance of De-Foiling Machine
sop for Preventive Maintenance of Strip Packing Machine
sop for Preventive Maintenance of Blister Packing Machine
sop for Preventive Maintenance of Capsule Polishing and Sorting Machine
sop for Preventive Maintenance of Capsule Filling Machine
sop for Preventive maintenance of Auto Coater
sop for Preventive Maintenance of Compression Machine
sop for preventive maintenance of packing conveyor belt
sop for Preventive Maintenance of Sifter Cum Multi mill
sop for Preventive Maintenance of Rapid Mixer Granulator
sop for Preventive Maintenance Of Fluid Bed Dryer
sop for Preventive Maintenance of Octagonal Blender
sop for Preventive Maintenance of Lifting and Positioning Device
sop for Preventive Maintenance of Paste Preparation vessel
sop for preventive maintenance of Vibro-Sifter
sop for preventive maintenance of air curtain
sop for preventive maintenance of air handling units
Preventive Maintenance of Diesel Generator
sop for Preventive Maintenance of cooling towers
sop for Preventive Maintenance of Boiler
sop for Preventive Maintenance of Air Compressor
sop for Preventive Maintenance of Chilling Plant
sop for Preventive Maintenance of Transformers
sop for Preventive maintenance of Purified Water System
sop for Break Down maintenance of Machine and Work Requisition
sop for Operation of Dust Extraction System
sop for Operation Of Effluent Treatment Plant
sop for Operation Of Diesel Generator
sop for Operation of Multi Column Distillation Plant
sop for Operation of Pure Steam Generator
sop for Operation of Air Handling Unit
sop for Operation of Cooling Tower
sop for Operation of Air Compressor
sop for Operation of Water Chilling Plant
sop for Cleaning of Pure Steam Generator
Cleaning of Over Head Water Tanks HDPE
sop for Cleaning of Water tanks
sop for Sanitization of multi column plant
sop for Sanitization of Ultrafiltration System
Sop for Chemical Sanitization of Reverse Osmosis
Sop for Sanitization of Hot Sanitization & Electro Deionization unit
sop for Sanitization of Purified Water Loop
sop for preparation of sodium meta bisulphate solution
sop for Testing of Hardness of Soft Water