sop for Operation of Boiler

sop for Operation of Boiler

1.0 Objective 
To lay down a procedure for Operation of Boiler
2.0 Scope
This Standard Operating Procedure is applicable for Operation of Boiler (Make: Forbes Marshall, Capacity 4500 Kg/hr) to be followed at formulation plants
3.0 Responsibility
3.1 Engineering Officer / Executive shall be responsible for the execution of this procedure.
3.2 Engineering Manager shall be responsible for the implementation of this SOP.
3.3 Head QA/designee shall be responsible for the compliance of this SOP.
4.0 Abbreviations and Definitions
SOP : Standard Operating Procedure etc
QA : Quality assurance
Ppm : Parts per million
kg/cm² : Kilo grams per Centimeter square
°C : Degree Celsius
ER : Engineering
TDS : Total Dissolved Solid
NMT : Not More Than
FO : Furnace oil
MCB : Miniature circuit Breaker
MCCB : Miniature Control circuit Breaker
HSD : High Speed Diesel

5.0 Procedure
5.1 Operation of boiler shall be carried out as per the requirement.
5.2 Boiler start and stop operation shall be performed as per the instruction from engineering Officer.
5.3 Operation of boiler:
5.3.1 Boiler can be operated with both FO and Diesel
5.3.2 Check the feed water quality. It shall be as follows.
5.3.2.1 Hardness – Less than5 PPM.
5.3.2.2 PH – Between 8.0 to 9.0
5.3.2.3 TDS- NMT 300PPM for feed water
5.3.2.4 TDS- NMT 3500 PPM For boiler blow down water
5.4 Operation Using FO
5.4.1 Check the level of boiler feed water tank and furnace oil day tank. Level shall be maintained above half level of the tank capacity in both feed water tank and furnace oil in Day Tank.
5.4.2 Open the outlet valve of boiler feed water tank and Furnace oil day tank.
5.4.3 Switch on MCCB, mounted on Boiler main panel & Switch on the MCB of Furnace oil day tank heater from boiler main panel.
5.4.4 FO day tank temperature should be in between 70-90oC .If temperature attains more than 90oC then switch off the MCB mounted on boiler panel for the power supply of Heaters.
5.4.5 Check water level Indicator (Gauge Glass) on water level indicator mounted on the boiler. It shall be always in between high and low levels marked on the level indicator sight glass.
5.4.6 Turn the selector switch and select Feed water pump no. 1 or 2 .Then put selector Switch marked as “F.P Control switch” in Auto mode.
5.4.7 Start main furnace oil pump.
5.4.8 Check that temperature setting of furnace oil is in between 100ºC to 120ºC, which can be seen by thermostat on temp controller.
5.4.9 Ensure the temperature setting of furnace oil is 100ºC cut-in and 125ºC cut – off mounted on boiler panel .Which can be seen by temperature indicator and controller.
5.4.10 Turn the selector switch to “ON” position mounted on boiler panel marked as “Heater ON/OFF”.
5.4.11 Turn the purging level to ‘P’ position i.e. to purging for 5 minutes.
5.4.12 Turn the burner ON/OFF selector switch mounted on boiler panel to ON position.
5.4.13 Turn the selector level to ‘A’ position i.e. in Auto Mode. Heater will cut off when FO temperature reaches below or above the set temperature. Boiler will restart after few seconds and boiler goes in firing mode.
5.4.14 Ensure that flame is established, which can be seen by view panel.
5.4.15 If not then boiler will go into the lock-out mode. Reset boiler by pressing push button.
5.4.16 Check that the steam pressure in the boiler is minimum 1.0 Kg/cm2. If it is less then open air relief valve.
5.4.17 Turn the firing rate control switch to low firing for 10 Min.
5.4.18 After 10 min, turn firing rate control switch to medium firing for 10min.
5.4.19 Close Air relief valve mounted above the boiler after steam pressure attends1.0Kg/cm².
5.4.20 Open steam stop valve when pressure gauge shows 5 Kg/cm2.
5.4.21 Turn firing rate control switch to “Auto mode” after one normal cut off by steam pressure switch.
5.4.22 Open blow down valve for 30-40 seconds after every 8 Hours of operation.
5.4.23 Drain water level indicator gauge glass after every operation of 8 Hours.
5.4.24 Drain mobbery water for 15 to 20 second by drain valve after every operation of 8 hours.
5.5 Stopping Procedure
5.5.1 Turn off the burner switch.
5.5.2 Switch off furnace oil circulation pump.
5.5.3 Switch off furnace oil preheated.
5.5.4 Maintain 80% water level in gauge glass which can be seen in water level Indicator.
5.5.5 Operate blow down valve for 30-40 seconds approx.
5.5.6 Drain mobbery water.
5.5.7 Close main steam stop valve. Water level should be 60-80% shown in water level Indicator.
5.5.8 Switch off main power supply which is mounted on boiler panel.
5.6 Operation Using Diesel
5.6.1 Check the level of boiler feed water tank and HSD oil tank. Level shall be maintained above half level of the tank capacity in both feed water tank and HSD oil in Day Tank
5.6.2 Open the outlet valve of boiler feed water tank and HSD oil Tank.
5.6.3 Ensure HSD day tank temperature should be between 10ºC – 15ºC.
5.6.4 Start main HSD oil pump.
5.6.5 Turn the selector switch on for firing.
5.6.6 At the time of this period oil heater should be switched off.
5.6.7 HSD temp should be maintained between 15 ºC – 25 ºC.
5.7 Stopping Procedure.
5.7.1 Turn off the burner switch.
5.7.2 Switch off HSD circulation pump.
5.7.3 Switch off Pre-heater.
5.7.4 Maintain 80% water level in gauge glass.
5.7.5 Operate blow down valve up to 30 to 40 seconds approx.
5.7.6 Drain mobbrey water.
5.7.7 Close main steam valve.
5.7.8 Switch off main power supply which is mounted on boiler panel.
5.8 Note down the operation parameter as per format no.



6.0 Forms and Records
6.1 Boiler Operation record – Annexure-1

7.0 Distribution
7.1 Master copy – Documentation Cell (Quality Assurance)
7.2 Controlled copies – Engineering Department

 sop for Execution of Preventive Maintenance

Preparation of Sodium Hydroxide Solution

sop for Breakdown Maintenance

sop for Handling of Filters

sop for water cooled chiller operation

cleaning and preventive maintenance of LAF and RLAF

sop for replacement of water system filters

cleaning and preventive maintenance of insectocutor

sop for operation of preventive maintenance

sop for material receiving and consumption record

sop for Preventive maintenance of bottle washing machine

sop for Replacement of Battery of Electronic Devices

sop for Preparation of R.O. Antiscalant Solution

Preventive Maintenance of Rapid Cooling Steam Sterilizer

Preventive Maintenance of Rapid cooling steam Generator

sop for Preventive Maintenance of Dust Collector

sop for Replacement of HVAC filters

SOP for Battery Backup in Mobile Laminar Air Flow Trolley

sop for Replacement of Tube lights

sop for Replacement of UV light of purified water plant

sop for Cleaning of soft water storage tank and RO feed tank

sop for Preparation of Sodium hydroxide Solution

sop for Operation and regeneration of softener plant

Procedure Of Issuance Of material from Engineering Store

sop for Preventive Maintenance of Filter Press

sop for Preventive Maintenance of Sugar Transfer System

sop for Preventive Maintenance of Shrink Sleeve Machine

sop for Preventive Maintenance of ROPP Cap Elevator

sop for Preventive Maintenance of Liquid Transfer Pumps

sop for Preventive Maintenance of Liquid Tanks

Preventive Maintenance of Strip De-Foiling Machine

sop for Preventive Maintenance of Colloidal Mill

sop for Preventive Maintenance of Packing Collator Belt

sop for Checking light intensity

sop for Operation of Fire- Extinguisher

sop for Passivation of WFI Distribution Loop

sop for Analysis of Effluent Treatment Plant Water

sop for Methodology to Dispose ETP Sludge

sop for Action Plan In Case Of Electrical Power Failure

sop for Colour Coding of Piping and Accessories of Utilities

sop for Replacement Policy

sop for Disposal of Engineering Waste

Filter Cleaning of HVAC System RLAF & LAF

Procedure for Calibration of Magnehelic Gauge

Procedure for Calibration of Vacuum Gauge

Procedure for Calibration of Pressure Gauge

sop for Procedure for Calibration of Temperature Controller

sop for Area Validation

sop for Preventive Maintenance of Infrared Dryer Umbrella Type

sop for Preventive Maintenance of Battery stacker

sop for Preventive Maintenance of Lift

sop for Preventive Maintenance of Vacuum Cleaner

sop for Preventive Maintenance of laminar air flow unit

sop for Preventive Maintenance of Lozenges Manufacturing Line

sop for Preventive Maintenance of Garment Washing Machine

sop for Preventive Maintenance of Multi Column Distillation Plant

sop for Preventive Maintenance of Steam Sterilizer Autoclave

sop for Preventive Maintenance of Pure steam Generator

sop for Preventive maintenance of Depyrogenating Tunnel

sop for Preventive Maintenance of vial sealing machine

sop for preventive maintenance of Powder Filling and Rubber Stoppering machine

sop for Preventive Maintenance of Vial Washing Machine

sop for Preventive Maintenance of Inspection Table

sop for Preventive Maintenance of Hi-Cart

sop for Preventive Maintenance of Turn table

sop for Preventive Maintenance of sticker labeling machine

sop for Preventive Maintenance of Liquid Filling and Sealing Machine

sop for Preventive Maintenance of Linear Bottle Washing Machine

sop for Preventive Maintenance of De-Foiling Machine

sop for Preventive Maintenance of Strip Packing Machine

sop for Preventive Maintenance of Blister Packing Machine

sop for Preventive Maintenance of Capsule Polishing and Sorting Machine

sop for Preventive Maintenance of Capsule Filling Machine 

sop for Preventive maintenance of Auto Coater

sop for Preventive Maintenance of Compression Machine

sop for preventive maintenance of packing conveyor belt

sop for Preventive Maintenance of Sifter Cum Multi mill

sop for Preventive Maintenance of Rapid Mixer Granulator

sop for Preventive Maintenance Of Fluid Bed Dryer

sop for Preventive Maintenance of Octagonal Blender

sop for Preventive Maintenance of Lifting and Positioning Device

sop for Preventive Maintenance of Paste Preparation vessel

sop for preventive maintenance of Vibro-Sifter

sop for preventive maintenance of air curtain

sop for preventive maintenance of air handling units

Preventive Maintenance of Diesel Generator

sop for Preventive Maintenance of cooling towers

sop for Preventive Maintenance of Boiler

sop for Preventive Maintenance of Air Compressor

sop for Preventive Maintenance of Chilling Plant

sop for Preventive Maintenance of Transformers

sop for Preventive maintenance of Purified Water System

sop for Break Down maintenance of Machine and Work Requisition

sop for Building Maintenance

sop for Operation of Lift

sop for Operation of Dust Extraction System

sop for Operation Of Effluent Treatment Plant

sop for Operation Of Diesel Generator

sop for Operation of Multi Column Distillation Plant

sop for Operation of Pure Steam Generator

sop for Operation of Air Handling Unit

sop for Operation of Cooling Tower

sop for Operation of Air Compressor

sop for Operation of Water Chilling Plant

sop for Operation of Boiler

sop for Cleaning of Pure Steam Generator

Cleaning of Over Head Water Tanks HDPE

sop for Cleaning of Water tanks

sop for Sanitization of multi column plant

sop for Sanitization of Ultrafiltration System

Sop for Chemical Sanitization of Reverse Osmosis

Sop for Sanitization of Hot Sanitization & Electro Deionization unit

sop for Sanitization of Purified Water Loop

sop for preparation of sodium meta bisulphate solution

sop for Testing of Hardness of Soft Water

sop for Operation & back wash of multi grade filter

sop for testing of chlorine contents in water

Leave a Comment

error: Content is protected !!